129 recommendations from completed CSB investigations are still open, sent to 40 recipients. Open means the CSB has not yet judged the response complete: some are awaiting a reply, some have an acceptable reply with work still under way.
Occupational Safety and Health Administration (OSHA) · 22 open
- 2005-4-I-TX-9Open - Unacceptable Response/No Response Received
Amend the OSHA PSM standard to require that a management of change (MOC) review be conducted for organizational changes that may impact process safety including: a. major organizational changes such as mergers, acquisitions, or reorganizations; b. personnel changes, including changes in staffing levels or staff experience; and c. policy changes such as budget cutting.
From BP America (Texas City) Refinery Explosion, March 23, 2005
- 2007-6-I-KS-1Open - Acceptable Response or Alternate Response
Revise the "Guidance for Hazard Determination for compliance with the OSHA Hazard Communication Standard" to advise chemical manufacturers and importers that prepare MSDSs to: -Evaluate flammable liquids to determine their potential to accumulate static electricity and form ignitable vapor-air mixtures in storage tanks. -Test the conductivity of the flammable liquid and include the testing results in the MSDS.
From Barton Solvents Explosions and Fire, July 17, 2007
- 2010-06-I-WV-2Open - Acceptable Response or Alternate Response
Take sustained measures to minimize the exposure of hazards to workers handling highly toxic gases from cylinders and associated regulators, gages, hoses, and appliances. Ensure that OSHA managers, compliance officers, equivalent state OSHA plan personnel, and regulated parties conform, under the Process Safety Management Standard (29 CFR 1910.119) Recognized and Generally Accepted Good Engineering Practices (RAGAGEP) provisions, to industry practices at least as effective as the following: NFPA 55 - Compressed Gases and Cryogenic Fluids Code (2010) CGA P-1 Safe Handling of Compressed Gases in Containers (2008) CGA E-9 Standard for Flexible, PTFE-lined Pigtails for Compressed Gas Service (2010) ASME B31.3 Process Piping (2008)
From DuPont Belle Toxic Chemical Releases, January 23, 2010
- 2013-02-I-TX-5Open - Awaiting Response or Evaluation/Approval of Response
Implement one of the following two regulatory changes, either option (a) or (b) below, to address FGAN hazards: a. Add FGAN to the OSHA Process Safety Management (PSM) standard List of Highly Hazardous Chemicals, Toxics and Reactives in 29 CFR 1910.119, Appendix A, and establish an appropriate threshold quantity. Identify National Fire Protection Association (NFPA) 400 as a source of Recognized and Generally Accepted Good Engineering Practices (RAGAGEP) for PSM-covered FGAN equipment and processes. b. Revise the OSHA Explosives and Blasting Agents standard, 29 CFR 1910.109, to ensure that the title, scope, or both make(s) clear that the standard applies to facilities that store bulk quantities of FGAN. Revise 1910.109(i), “Storage of Ammonium Nitrate,” to include requirements similar to those in NFPA 400, Hazardous Materials Code (2016 Edition), Chapter 11. Ensure the following elements are considered: i. For new construction, prohibit combustible materials of construction for FGAN facilities and FGAN bins. For existing facilities, establish a phase-in requirement for the replacement of wooden bins with bins made of noncombustible materials of construction within a reasonable time period (e.g., 3 to 5 years from the date standard revisions are enacted), based on feedback from the fertilizer industry. ii. Require automatic fire sprinkler systems and fire detection systems for indoor FGAN storage areas. iii. Define adequate ventilation for FGAN for indoor storage areas. iv. Require all FGAN storage areas to be isolated from the storage of combustible, flammable, and other contaminating materials. v. Establish separation distances between FGAN storage areas and other hazardous chemicals, processes, and facility boundaries.
From West Fertilizer Explosion and Fire, April 17, 2013
- 2017-07-I-WI-10Open - Awaiting Response or Evaluation/Approval of Response
Promulgate a standard for all industries that handle combustible dust, which should be based on the requirements of current NFPA combustible dust standards, including NFPA 61, Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Processing Facilities, NFPA 484, Standard for Combustible Metals, NFPA 652, Standard on the Fundamentals of Combustible Dust, NFPA 654, Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids, NFPA 655, Standard for Prevention of Sulfur Fires and Explosions, NFPA 664, Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities, or a successor standard. At a minimum, the standard should include the following elements: a. Hazard Recognition; b. Dust Hazard Analysis; c. Management of Change; d. Incident Investigation; e. Engineering Controls; f. Building Design; g. Fugitive Dust Management; h. Operating Procedures; i. Process Safety Information; j. External Audit Management; k. Training; l. Emergency Response; and m. Personal Protective Equipment. (Superseded the following recommendations: 2006-1-H-R1 from the Combustible Dust Hazard investigation, 2008-05-I-GA-R11 from the Imperial Sugar investigation, and 2011-04-I-TN-R1 and 2011-04-I-TN-R2 from the Hoeganaes Corporation investigation)
From Didion Milling Company Explosion and Fire, May 31, 2017
- 2017-07-I-WI-11Open - Awaiting Response or Evaluation/Approval of Response
Following implementation of CSB Recommendation No. 2017-07-I-WI-R10, update the Grain Handling Facilities Standard to clarify grain handling facilities with combustible dust are covered by the new Combustible Dust Standard.
From Didion Milling Company Explosion and Fire, May 31, 2017
- 2017-07-I-WI-12Open - Awaiting Response or Evaluation/Approval of Response
Develop a program to trigger follow-up inspections when hazard alert letters are issued for combustible dust hazards and there is insufficient evidence to demonstrate that those hazards have been abated.
From Didion Milling Company Explosion and Fire, May 31, 2017
- 2018-02-I-WI-11Open - Awaiting Response or Evaluation/Approval of Response
Develop guidance documents for performing process hazard analysis on operating procedures to address transient operation hazards in facilities with Process Safety Management (PSM) covered processes.
From Husky Energy Superior Refinery Explosion and Fire, April 26, 2018
- 2019-01-I-TX-7Open - Awaiting Response or Evaluation/Approval of Response
Eliminate the atmospheric storage tank exemption from the PSM standard. (Superseded 2001-05-I-DE-R1 from the Motiva report and 2010-02-I-PR-R4 from the Caribbean Petroleum (CAPECO) report )
From Intercontinental Terminals Company (ITC) Tank Fire, March 17, 2019
- 2024-01-H-3Open - Awaiting Response or Evaluation/Approval of Response
Update the Process Safety Management (PSM) standard by expanding the Process Hazard Analysis (PHA) requirements under 29 CFR 1910.119(e)(3) to include an evaluation of the need for remote isolation devices for major process equipment that can be remotely activated from a safe location or automatically activated during a release.
From CSB Safety Study: Remote Isolation of Process Equipment, November 27, 2019
- 2020-04-I-TX-3Open - Awaiting Response or Evaluation/Approval of Response
Remove the exemption for oil and gas drilling and well servicing from the Control of Hazardous Energy standard (29 CFR 1910.147) and expand its applicability to cover oil and gas production and workover operations.
From Wendland 1H Well Fatal Explosion, January 29, 2020
- 2020-04-I-TX-4Open - Awaiting Response or Evaluation/Approval of Response
Promulgate a new standard with prescriptive requirements, similar to the Control of Hazardous Energy Standard, as well as a performance-based safety management system framework, similar to the OSHA Process Safety Management (PSM) Standard, that applies to the drilling, production, and servicing/workover activities surrounding onshore oil and gas wells. At a minimum, this standard should include the following: 1. Prescriptively address requirements for primary and secondary barriers for well control; 2. Detailed written drilling, production, and servicing procedures with specified steps and equipment alignment for all operations; 3. Management of change requirements (except replacements in kind) that, at a minimum, address procedures, the well plan, and equipment; 4. A risk assessment of hazards associated with the drilling, production, and servicing/workover plans; 5. A requirement to follow Recognized and Generally Accepted Good Engineering Practices (RAGAGEP); 6. Development of a Well Construction Interface Document between the operator and the drilling contractor prior to the commencement of drilling and servicing activities and an equivalent document for production and workover contractors which, at a minimum, includes a bridging document and well plans specifying barriers and how to manage them; 7. The performance and documentation of flow checks using acceptable methods at defined points during the operation for a specified duration; 8. A requirement for employee participation, similar to the Employee Participation requirement in the OSHA PSM standard; 9. A requirement for maintaining critical well information, similar to the Process Safety Information requirement in the OSHA PSM standard, which at a minimum includes well history and documented well control methods during workovers; 10. A requirement for analyzing and assessing the hazards during all phases and steps for well servicing, similar to the Process Hazard Analysis requirement in the OSHA PSM standard; 11. A requirement for developing, executing, communicating, and maintaining procedures for drilling, production, and servicing operations on a well, similar to the Operating Procedures requirement in the OSHA PSM standard; and 12. The documentation of well control plans for drilling, production, and servicing/workover operations for a well utilizing acceptable methods for monitoring the effectiveness of well control methods. (Superseded 2018-01-I-OK-R1 )
From Wendland 1H Well Fatal Explosion, January 29, 2020
- 2021-01-I-TN-1Open - Awaiting Response or Evaluation/Approval of Response
Promulgate a standard or modify existing standards to require employers to ensure the coordination of simultaneous operations (SIMOPs) involving multiple work groups, including contractors. Ensure that the requirements of this standard or standards apply to both general industry and construction activities and are not limited to activities occurring within confined spaces. Include in the standard requirements for Employers to ensure that the following activities occur: a. Identification of potential SIMOPs; b. Identification of potential hazardous interactions; c. Evaluation and implementation of necessary safeguards to allow for safe SIMOPs; d. Coordination, including shared communication methods, between the SIMOPs; and e. Inclusion of emergency response personnel or services in the planning and coordination of the SIMOPs. (Superseded 2020-7-I-NC-R2 from the Evergreen report)
From Wacker Polysilicon Chemical Release, November 13, 2020
- 2021-01-I-TN-2Open - Awaiting Response or Evaluation/Approval of Response
Develop a safety product providing guidance on the coordination of simultaneous operations (SIMOPs) involving multiple work groups, including contractors, that is not limited to confined space or construction. Provide guidance on the following activities: a. Identification of potential SIMOPs; b. Identification of potential hazardous interactions; c. Evaluation and implementation of necessary safeguards to allow for safe SIMOPs; d. Coordination, including shared communication methods, between the SIMOPs; and e. Inclusion of emergency response personnel or services in the planning and coordination of the SIMOPs.
From Wacker Polysilicon Chemical Release, November 13, 2020
- 2021-02-I-WV-11Open - Awaiting Response or Evaluation/Approval of Response
Update the Chemical Reactivity Hazards website ( https://www.osha.gov/chemical-reactivity ) to include various reactivity assessment tools developed since the 2002 Index-Based Method for Assessing Exothermic Runaway Risk and the 2004 Preliminary Screening Method. Mathematical methods, thermal analysis methods (e.g., Accelerating Rate Calorimeter (ARC) testing), ASTM E1231-19 Standard Practice for Calculation of Hazard Potential Figures of Merit for Thermally Unstable Materials, Stoessel Criticality, and the O.R.E.O.S. Method (an assessment that combines Oxygen balance calculations, the Rule of 6, and the Explosive functional group list with Onset decomposition and scale) are tools that could be considered for the update. The “Additional Resources” section of the website should also be evaluated for necessary changes and updates.
From Optima Belle Explosion and Fire, December 8, 2020
- 2021-02-I-WV-12Open - Awaiting Response or Evaluation/Approval of Response
Following the implementation of CSB recommendation 2021-02-I-WV-R11, ensure that the chemical industry is aware of the Chemical Reactivity Hazards website ( https://www.osha.gov/chemical-reactivity ) by developing and implementing a comprehensive outreach plan that actively targets the chemical industry and related trade associations. The outreach plan may include such means as a national news release and OSHA’s “QuickTakes” newsletter and/or Safety and Health Information Bulletins. This outreach plan should be coordinated with OSHA’s On-Site Consultation Program partners.
From Optima Belle Explosion and Fire, December 8, 2020
- 2021-02-I-WV-13Open - Awaiting Response or Evaluation/Approval of Response
Amend the Process Safety Management (PSM) Standard, 29 CFR 1910.119, to achieve more comprehensive control of reactive hazards that could have catastrophic consequences. Broaden the application to cover reactive hazards resulting from process-specific conditions and combinations of chemicals. Additionally, broaden coverage of hazards from self-reactive chemicals. In expanding PSM coverage, use objective criteria. Consider criteria such as the North American Industry Classification System (NAICS), a reactive hazard classification system (e.g., based on heat of reaction or hazardous gas evolution), incident history, or catastrophic potential. In the compilation of process safety information, require that multiple sources of information be sufficiently consulted to understand and control potential reactive hazards. Useful sources include but are not limited to: - Literature surveys (e.g., Bretherick’s Handbook of Reactive Chemical Hazards, Sax’s Dangerous Properties of Industrial Materials, CAS SciFinder). - Information developed from computerized tools (e.g., ASTM’s CHETAH, CCPS’s Chemical Reactivity Worksheet). - Chemical property data compiled in PubChem and the REACH (Registration, Evaluation, and Authorization of Chemicals) dossiers maintained by the European Chemicals Agency (ECHA). - Chemical reactivity test data produced by employers or obtained from other sources following established standards such as: - ASTM E537-20, Standard Test Method for Chemicals by Differential Scanning Calorimetry; - ASTM E1981-22, Standard Guide for Assessing Thermal Stability of Materials by Methods of Accelerating Rate Calorimetry; - ASTM E2550-21, Standard Test Method for Thermal Stability by Thermogravity; and - ASTM E1231-19, Standard Practice for Calculation of Hazard Potential Figures of Merit for Thermally Unstable Materials. - Relevant incident data from the plant, the corporation, industry, and government. Augment the process hazard analysis (PHA) element to explicitly require an evaluation of reactive hazards. In revising this element, evaluate the need to consider relevant factors, such as: - Rate and quantity of heat or gas generated. - Maximum operating temperature to avoid a runaway reaction from decomposition. - Time to Maximum Rate under Adiabatic Conditions (TMRad). - Thermal stability of reactants, reaction mixtures, byproducts, waste streams, and products. - Effect of variables such as charging rates, catalyst addition, and possible contaminants. - Understanding the consequences of runaway reactions or hazardous gas evolution. (Superseded 2001-01-H-XX-R1)
From Optima Belle Explosion and Fire, December 8, 2020
- 2021-03-I-GA-4Open - Awaiting Response or Evaluation/Approval of Response
Update the Region 4 Poultry Processing Facilities Regional Emphasis Program to explicitly cover liquid nitrogen freezing processes. At a minimum, the update should encourage practices applicable to managing the hazards of using liquid nitrogen and other cryogenic asphyxiants, including process safety management practices, atmospheric monitoring, employee training and hazard awareness, and emergency preparedness and response.
From Foundation Food Group Fatal Chemical Release, January 28, 2021
- 2021-03-I-GA-5Open - Awaiting Response or Evaluation/Approval of Response
Update the Region 5 Regional Emphasis Program for Food Manufacturing Industry to explicitly cover liquid nitrogen freezing processes. At a minimum, the update should encourage practices applicable to managing the hazards of using liquid nitrogen and other cryogenic asphyxiants, including process safety management practices, atmospheric monitoring, employee training and hazard awareness, and emergency preparedness and response.
From Foundation Food Group Fatal Chemical Release, January 28, 2021
- 2021-03-I-GA-6Open - Awaiting Response or Evaluation/Approval of Response
Update the Region 6 Poultry Processing Facilities Regional Emphasis Program to explicitly cover liquid nitrogen freezing processes. At a minimum, the update should encourage practices applicable to managing the hazards of using liquid nitrogen and other cryogenic asphyxiants, including process safety management practices, atmospheric monitoring, employee training and hazard awareness, and emergency preparedness and response.
From Foundation Food Group Fatal Chemical Release, January 28, 2021
- 2021-03-I-GA-7Open - Awaiting Response or Evaluation/Approval of Response
Promulgate a standard specific to cryogenic asphyxiants. The purpose of this standard shall be the prevention and/or mitigation of hazards arising from the storage, use, and/or handling of these substances. The new standard shall reference applicable national consensus standards such as those published by the Compressed Gas Association and others, as appropriate. At a minimum the new standard shall: a) Address requirements for the design, construction, and installation of process equipment storing or using cryogenic asphyxiants; b) Require atmospheric monitoring where equipment storing or using cryogenic asphyxiants is located indoors; c) Require emergency shutdown systems such that equipment storing or using cryogenic asphyxiants may be isolated during a release without endangerment; d) Address requirements for employee training and hazard awareness specific to cryogenic asphyxiants; e) Require an emergency action plan in accordance with 29 CFR 1910.38; and, f) Address requirements for the use of process safety management elements such as process hazard analysis, management of change, procedures, and others deemed necessary through the rulemaking process to prevent and/or mitigate these hazards.
From Foundation Food Group Fatal Chemical Release, January 28, 2021
- 2021-03-I-GA-8Open - Awaiting Response or Evaluation/Approval of Response
Develop and publish a Guidance Document (similar to OSHA 3912-03 Process Safety Management for Explosives and Pyrotechnics Manufacturing) for process safety management practices applicable to processes handling compressed gases and cryogenic asphyxiants, including (at a minimum) the practices highlighted in this report.
From Foundation Food Group Fatal Chemical Release, January 28, 2021
Environmental Protection Agency (EPA) · 9 open
- 2001-01-H-3Open - Acceptable Response or Alternate Response
Revise the Accidental Release Prevention Requirements, 40 CFR 68, to explicitly cover catastrophic reactive hazards that have the potential to seriously impact the public, including those resulting from self-reactive chemicals and combinations of chemicals and process-specific conditions. Take into account the recommendations of this report to OSHA on reactive hazard coverage. Seek congressional authority if necessary to amend the regulation.
From Improving Reactive Hazard Management, August 1, 2000
- 2010-08-I-WA-3Open - Awaiting Response or Evaluation/Approval of Response
Develop guidance for the required use of inherently safer systems analysis and the hierarchy of controls for enforcement under 40 CFR Part 68 and the Clean Air Act’s General Duty Clause, section 112(r)(1),42 U.S.C. §7412(r)(1).
From Tesoro Anacortes Refinery Fatal Explosion and Fire, April 2, 2010
- 2013-02-I-TX-3Open - Acceptable Response or Alternate Response
Revise the Risk Management Program rule to include fertilizer grade ammonium nitrate (FGAN) at an appropriate threshold quantity on the List of Regulated Substances. a. Ensure that the calculation for the offsite consequence analysis considers the unique explosive characteristics of FGAN explosions to determine the endpoint for explosive effects and overpressure levels. Examples of such analyses include that adopted by the 2014 Fire Protection Research Foundation report, “Separation Distances in NFPA Codes and Standards,” Great Britain’s Health and Safety Executive, and other technical guidance. b. Develop Risk Management Program rule guidance document(s) for regulated FGAN facilities.
From West Fertilizer Explosion and Fire, April 17, 2013
- 2018-02-I-WI-12Open - Acceptable Response or Alternate Response
Develop a program that prioritizes and emphasizes inspections of FCC units in refineries that operate HF alkylation units (for example, under EPA’s National Compliance Initiative called Reducing Risks of Accidental Releases at Industrial and Chemical Facilities). As part of this program, verify FCC unit safeguards that prevent explosions during transient operation (including startup, shutdown, standby, and emergency procedures). At a minimum the program will verify the following specific safeguards: a) Implementation of the reactor steam barrier, or a similar inert gas flow, to maintain an inert barrier at an elevated pressure between the main column (containing hydrocarbon) and the regenerator (containing air); b) Purging the main column with a non-condensable gas as needed to prevent a dangerous accumulation of oxygen in the main column overhead receiver; c) Monitoring to ensure that there is a sufficient non-condensable gas purge of the main column to prevent a dangerous accumulation of oxygen in the main column overhead receiver (either through direct measurement of the oxygen concentration and/or through engineering calculation); d) Monitoring of critical operating parameters for flows, pressures, pressure differences, and catalyst levels; e) Documentation of consequences of deviating from the transient operation safe operating parameters and of predetermined corrective actions; and f) Inclusion of the above items in the appropriate FCC operator training curricula. This recommendation is in addition to the recommendations to EPA relating to hydrofluoric acid outlined in the CSB’s report on the 2019 fire and explosions at the Philadelphia Energy Solutions refinery. In that report, the CSB recommended (1) that the EPA prioritize inspections of refinery HF alkylation units to ensure units are complying with API good practice guidance, (2) to require petroleum refineries with HF alkylation units to evaluate inherently safer technology, and (3) to initiate prioritization and, as applicable, risk evaluation of HF under the Toxic Substances Control Act.
From Husky Energy Superior Refinery Explosion and Fire, April 26, 2018
- 2019-01-I-TX-8Open - Awaiting Response or Evaluation/Approval of Response
Modify 40 C.F.R. §68.115(b)(2)(i) to expand coverage of the RMP rule to include all flammable liquids, including mixtures, with a flammability rating of NFPA-3 or higher. (Superseded 2010-02-I-PR-R1 from the Caribbean Petroleum (CAPECO) report)
From Intercontinental Terminals Company (ITC) Tank Fire, March 17, 2019
- 2019-04-I-PA-1Open - Acceptable Response or Alternate Response
Develop a program that prioritizes and emphasizes inspections of refinery HF alkylation units, for example under EPA’s National Compliance Initiative called Reducing Risks of Accidental Releases at Industrial and Chemical Facilities. As part of this program, verify that HF alkylation units are complying with API RP 751 Safe Operation of Hydrofluoric Acid Alkylation Units, including but not limited to the implementation of a special emphasis inspection program to inspect all individual carbon steel piping components and welds to identify areas of accelerated corrosion; the protection of safety-critical safeguards and associated control system components, including but not limited to wiring and cabling for control systems and primary and backup power supplies, from fire and explosion hazards including radiant heat and flying projectiles (per recommendation 2019-04-I-PA-R4); and the installation of remotely-operated emergency isolation valves on the inlet(s) and outlet(s) of all hydrofluoric acid containing vessels, and hydrocarbon containing vessels meeting defined threshold quantities (per recommendation 2019-04-I-PA-R4).
From Philadelphia Energy Solutions (PES) Refinery Fire and Explosions, June 21, 2019
- 2024-01-H-2Open - Awaiting Response or Evaluation/Approval of Response
Update the Risk Management Program (RMP) rule by expanding the requirements of 40 CFR Part 68 to include an evaluation of the need for remote isolation devices for major process equipment that can be remotely activated from a safe location or automatically activated during a release. The evaluation should be included in hazard assessments, hazard reviews, and process hazard analyses.
From CSB Safety Study: Remote Isolation of Process Equipment, November 27, 2019
- 2020-05-I-LA-6Open - Awaiting Response or Evaluation/Approval of Response
Implement the five open recommendations issued in the 2022 U.S. Government Accountability Office Report titled Chemical Accident Prevention: EPA Should Ensure Regulated Facilities Consider Risks from Climate Change, which are: a. The U.S. Environmental Protection Agency (EPA) should provide additional compliance assistance to Risk Management Program (RMP) facilities related to risks from natural hazards and climate change; b. The EPA should design an information system to track common deficiencies found during inspections, including any related to natural hazards and climate change, and use this information to target compliance assistance; c. The EPA should issue regulations, guidance, or both, as appropriate, to clarify requirements and provide direction for RMP facilities on how to incorporate risks from natural hazards and climate change into their risk management programs; d. The EPA should develop a method for inspectors to assess the sufficiency of RMP facilities’ incorporation of risks from natural hazards and climate change into risk management programs and provide related guidance and training to inspectors; and e. The EPA should incorporate the vulnerability of RMP facilities to natural hazards and climate change as criteria when selecting facilities for inspection.
From Bio-Lab Lake Charles Chemical Fire and Release, August 27, 2020
- 2023-02-I-LA-4Open - Awaiting Response or Evaluation/Approval of Response
Per the requirements in EPA Rule Procedures for Prioritization of Chemicals for Risk Evaluation Under the Toxic Substances Control Act, initiate prioritization to evaluate whether hydrogen fluoride, including its anhydrous and aqueous acid forms, is a High-Priority Substance for risk evaluation. If it is determined to be a High-Priority Substance, conduct a risk evaluation of hydrogen fluoride to determine whether it presents an unreasonable risk of injury to health or the environment. If it is determined to present an unreasonable risk of injury to health or the environment, apply requirements to hydrogen fluoride to the extent necessary to eliminate or significantly mitigate the risk, for example by using a methodology such as the hierarchy of controls. (Supersedes 2019-04-I-PA-R3 from the Philadelphia Energy Solutions Report)
From Honeywell Geismar Chlorine and Hydrogen Fluoride Releases, January 23, 2023
American Petroleum Institute (API) · 7 open
- 2010-10-I-OS-5Open - Acceptable Response or Alternate Response
Based on the analysis presented in the CSB Macondo investigation report, Volumes 3 and 4, and the requirements listed in R11, revise Recommended Practice 75, Development of a Safety and Environmental Management Program for Offshore Operations and Facilities, 3rd ed., May 2004 (reaffirmed May 2008), to require a specific focus on major accident prevention and address the following issues: a. Incorporate the following listed safety management system issues as explicit program elements and include language throughout API 75 regarding each element’s explicit and defined applicability to all of the other existing program elements: 1. Human factors program requirements for the design, planning, execution, management, assessment, and decommissioning of well operations for the prevention of major accidents, as well as in the investigation of accidents and near-misses; 2. Corporate governance and Board of Director responsibilities for major accident risk management; 3. Workforce involvement and engagement in all aspects of the SEMS program; 4. Contractor oversight and effective coordination for major accident prevention; and 5. Leading and lagging key performance indicators that drive major accident prevention. b. Define and expand the roles and responsibilities for major accident prevention among the primary parties engaged in offshore drilling and production (i.e., the leaseholder/operator and owner/drilling contractor) by expanding applicability of this standard to the parties with primary control over major hazard operations and day-to-day activities and thus best positioned to implement and oversee a safety and environmental management system (SEMS) program to control major accident hazards. c. Incorporate into the Principles section of the document, as well as within the Setting Objectives and Goals section, as overarching provisions for the overall successful implementation and execution of a SEMS program: 1. Management of major accident risk to As Low As Reasonably Practicable or similar risk-reduction target; 2. Use the hierarchy of controls for identifying, establishing, and implementing barriers meant to prevent or mitigate major accident hazards.
From Macondo Blowout and Explosion, April 20, 2010
- 2019-04-I-PA-4Open - Awaiting Response or Evaluation/Approval of Response
Update API RP 751 Safe Operation of Hydrofluoric Acid Alkylation Units to require the following: Protection of critical safeguards and associated control system components, including but not limited to wiring and cabling for control systems and primary and backup power supplies, from fire and explosion hazards, including radiant heat and flying projectiles; and Installation of remotely-operated emergency isolation valves on the inlet(s) and outlet(s) of all hydrofluoric acid containing vessels, and hydrocarbon containing vessels meeting defined threshold quantities.
From Philadelphia Energy Solutions (PES) Refinery Fire and Explosions, June 21, 2019
- 2020-04-I-TX-2Open - Awaiting Response or Evaluation/Approval of Response
Publish the following information in an appropriate document such as API RP 59 Recommended Practice for Well Control Operations: 1. A focused discussion on practices applicable to workover operations, including completed wells in underpressured reservoirs. Include well control methods applicable to workover operations, such as using continuous fluid addition, viscous fluids, bridging solids, and mechanical plugs. Also include a discussion on the well control challenges and hazards specific to workover operations; 2. Stabbing valves should not be considered as well control barriers for workover operations; and 3. Every well should be considered to have potential to flow, and therefore, should have two well control barriers, one of which should be a preventative barrier.
From Wendland 1H Well Fatal Explosion, January 29, 2020
- 2021-04-I-OH-6Open - Awaiting Response or Evaluation/Approval of Response
Develop specific design, construction, and alteration guidance for low-pressure process vessels in flammable and other highly hazardous chemicals service not exceeding an internal pressure of 15 psig in API 510 Pressure Vessel Inspection Code, API RP 572 Inspection Practices for Pressure Vessels, and/or other appropriate products. At a minimum, include guidance for: (i) determining and documenting the low-pressure vessel’s design pressure (such as through a data sheet and a nameplate affixed to the vessel); (ii) determining when or if all or parts of the ASME Boiler and Pressure Vessel Code should be applied; (iii) acceptable alternative engineering methods, if applicable; and, (iv) alteration requirements, such as design assessments, inspections, and pressure testing.
From Yenkin-Majestic Resin Plant Vapor Cloud Explosion and Fire, April 8, 2021
- 2022-01-I-OH-5Open - Awaiting Response or Evaluation/Approval of Response
Develop a new publication or revise an existing publication, such as API Recommended Practice 556 Instrumentation, Control, and Protective Systems for Gas Fired Heaters, to incorporate the process hazards associated with Fuel Gas Mix Drum overflow. The publication should include the following at a minimum: a) Description of the process hazards associated with Fuel Gas Mix Drum overflow and the consequential impacts on equipment using fuel gas, b) Guidance for Fuel Gas Mix Drum design and sizing criteria which includes consideration of condensation, entrainment, overflow, and draining, c) Guidance for instrumentation to detect high level to prevent overfilling of Fuel Gas Mix Drums, and d) Recommended practices for selecting preventive safeguards to prevent overfilling of Fuel Gas Mix Drums.
From BP - Husky Oregon Chemical Release and Fire, September 20, 2022
- 2022-01-I-OH-6Open - Acceptable Response or Alternate Response
Develop a publication that addresses preventing the overflow of pressure vessels such as towers and drums. The publication should be applicable to both new and existing pressure vessels. Include the following at a minimum: a) Description of typical overflow events that could result during normal, upset, or transient operations (startup, shutdown, standby) including the formation of a vapor cloud, b) Recommended practices for instrumentation to monitor and detect a pressure vessel overflow, c) Process hazard analysis guidance for pressure vessel overflow scenarios, d) Recommended practices for safeguards to prevent a pressure vessel overflow, e) Recommended field and board operator process safety training topics and methods to prevent a pressure vessel overflow, f) Guidelines for process safety assessments to prevent a pressure vessel overflow, and g) Incorporate lessons learned from this CSB investigation and the CSB’s BP Texas City Refinery investigation throughout the document.
From BP - Husky Oregon Chemical Release and Fire, September 20, 2022
- 2024-01-I-CA-8Open - Awaiting Response or Evaluation/Approval of Response
Revise API RP 556 Instrumentation, Control, and Protective Systems for Gas Fired Heaters, or successor API products, with the following: Requirements for proper response to high tube metal temperatures, including guidance to alert operators when safe operating limits are exceeded and to specify predetermined response actions, such as shutting down the fired heater remotely. The predetermined response actions must include actions that specify when to stop troubleshooting and remove personnel from the vicinity of the fired heater; Design requirements (“shall” rather than “should” language) for protecting fired heaters from low process flow where process piping diverges downstream of a flow meter. Requirements may include achieving proof of flow to the heater through valve position indicators and interlocks on branch Engineering safeguard requirements (“shall” rather than “should” language) to detect and prevent afterburning in fired heaters. These requirements may include the use of instrumentation such as combustibles measurements, flame detectors, and/or thermocouples that measure tube metal, flue gas, and process fluid temperatures. The requirements shall address monitoring capability from the control room.
From Marathon Martinez Renewable Fuels Fire, November 19, 2023
Givaudan Caramel Coloring Facilities · 7 open
- 2024-06-I-KY-1Open - Awaiting Response or Evaluation/Approval of Response
Contract a third party to analyze the reactivity of the sugar ingredients in the caramel coloring product manufacturing process by, at a minimum: a. Conducting calorimetry testing on at least one representative recipe for all caramel coloring product types to determine their temperature and pressure behavior upon heating. b. Testing the composition of any produced non-condensable gases. Maintain this information for use during future equipment design efforts and hazard analyses.
From Givaudan Sense Colour Explosion, November 12, 2024
- 2024-06-I-KY-2Open - Awaiting Response or Evaluation/Approval of Response
Contract a third party to conduct a hazard analysis of each caramel coloring facility. Require this analysis to address reactivity hazards and include a review of the reactivity data obtained from implementing CSB Recommendation 2024-06-I-KY-R1. Implement the recommendations issued by the third party as a result of the hazard analyses.
From Givaudan Sense Colour Explosion, November 12, 2024
- 2024-06-I-KY-3Open - Awaiting Response or Evaluation/Approval of Response
Contract a third party to develop a process safety management system to be used at each caramel coloring facility. This third party shall: a. Ensure the process safety management system is in alignment with current industry guidance such as the CCPS’s Guidelines for Risk Based Process Safety. b. Ensure that the process safety management system requires hazard reviews/analyses to be conducted at prescribed intervals and include: (1) the review/incorporation of reactivity data from CSB Recommendation 2024-06-I-KY-R1 and any additional reactivity data obtained during the course of operating any caramel coloring facility, (2) the review/analysis of any process changes that could affect relief system designs, and (3) the review/updating of the facility siting study from CSB Recommendation 2024-06-I-KY-R7, as appropriate.
From Givaudan Sense Colour Explosion, November 12, 2024
- 2024-06-I-KY-4Open - Awaiting Response or Evaluation/Approval of Response
At each caramel coloring facility, hire a new or identify a current employee who is competent in process safety management concepts. Establish this employee’s job duties to specifically include overseeing the caramel coloring facility’s process safety management system established in 2024-06-I-KY-R3, its implementation, and personnel training on the system’s elements.
From Givaudan Sense Colour Explosion, November 12, 2024
- 2024-06-I-KY-5Open - Awaiting Response or Evaluation/Approval of Response
For each caramel coloring facility, contract a third party to design adequate emergency pressure relief systems for the vessels involved in caramel coloring manufacturing. Ensure the third party reviews/incorporates all reactivity data obtained from the testing required by CSB Recommendation 2024-06-I-KY-R1 when designing the emergency pressure relief systems. Document and maintain each vessel’s relief system design basis for the service life of the vessel.
From Givaudan Sense Colour Explosion, November 12, 2024
- 2024-06-I-KY-6Open - Awaiting Response or Evaluation/Approval of Response
For each caramel coloring facility, establish automatic alerts, such as alarms or control screen indications, to notify operators when a safe operating limit has been reached. Follow industry guidance, such as the guidance presented in the Center for Chemical Process Safety Book Guidelines for Engineering Design for Process Safety (2nd Edition), Chapter 5 General Design. Provide initial and refresher training for operations personnel on the established safe operating limits including the actions to take if these limits are exceeded.
From Givaudan Sense Colour Explosion, November 12, 2024
- 2024-06-I-KY-7Open - Awaiting Response or Evaluation/Approval of Response
Contract a third party to conduct a facility siting study before constructing caramel coloring facility(ies) to help protect facility occupants and critical equipment from hazards created by explosion, fire, or toxic material release, using published industry guidance, such as that in the Center for Chemical Process Safety book, Guidelines for Siting and Layout of Facilities.
From Givaudan Sense Colour Explosion, November 12, 2024
National Fire Protection Association (NFPA) · 7 open
- 2021-01-I-TN-10Open - Awaiting Response or Evaluation/Approval of Response
Revise NFPA 101 Life Safety Code, NFPA 55 Compressed Gases and Cryogenic Fluids Code, or NFPA 400 Hazardous Materials Code to address conditions which may require multiple means of egress from elevated industrial structures containing hazardous materials posing physical and health hazards, regardless of their combustibility, burn rate, or likelihood of explosion. The guidance should address egress situations for workers on unwalled, elevated structures in the presence of materials posing physical and health hazards. Specify the minimum number of egress points to increase the likelihood of worker escape in the event of a hazardous material release.
From Wacker Polysilicon Chemical Release, November 13, 2020
- 2021-03-I-GA-11Open - Acceptable Response or Alternate Response
Update NFPA 55 Compressed Gases and Cryogenic Fluids Code to: a) require the use of atmospheric monitoring with cryogenic asphyxiants in accordance with industry guidance such as is contained in CGA P-76 Hazards of Oxygen-Deficient Atmospheres and CGA P-12 Safe Handling of Cryogenic Liquids in addition to CGA P-18 Standard for Bulk Inert Gas Systems; and, b) include guidance on the adequate safe location of manual shutoff valves and devices such as emergency push buttons used to activate remotely operated emergency isolation valves (ROEIVs). At a minimum this guidance should be harmonized with the requirements of ISO 13850 Safety of machinery – Emergency stop function – Principles for design.
From Foundation Food Group Fatal Chemical Release, January 28, 2021
- 2023-03-I-LA-2Open - Awaiting Response or Evaluation/Approval of Response
Update NFPA 350 Guide for Safe Confined Space Entry and Work to provide guidance on how to ensure that vessels that have undergone confined space entry are left clean and ready for startup after the entries are completed.
From Dow Louisiana Operations Explosions, July 14, 2023
- 2023-03-I-LA-3Open - Awaiting Response or Evaluation/Approval of Response
Update NFPA 326 Standard for the Safeguarding of Tanks and Containers for Entry, Cleaning, or Repair to provide requirements for to ensure that vessels that have undergone confined space entry are left clean and ready for startup after the entries are completed.
From Dow Louisiana Operations Explosions, July 14, 2023
- 2024-04-I-GA-5Open - Awaiting Response or Evaluation/Approval of Response
Revise NFPA 400 Hazardous Materials Code, Section 4.1 Hazardous Material Classification, or a more appropriate section, to clarify that materials are required to be assessed and a determination reached for each of the categories of hazardous materials (1) through (14).
From Bio-Lab Inc. Conyers Fire and Chemical Release, September 29, 2024
- 2024-04-I-GA-6Open - Awaiting Response or Evaluation/Approval of Response
Revise NFPA 400 Hazardous Materials Code, Section G.4 Safety Information on Oxidizers Used in Swimming Pools, to address the potential for pool-treatment chemicals to demonstrate characteristics of hazard classifications other than those of oxidizers, and that each additional hazard classification must conform to the code requirements for each applicable hazardous material classification in accordance with Section 4.4 Multiple Hazards.
From Bio-Lab Inc. Conyers Fire and Chemical Release, September 29, 2024
- 2024-04-I-GA-7Open - Awaiting Response or Evaluation/Approval of Response
Revise NFPA 400 Hazardous Materials Code, Section G.4 Safety Information on Oxidizers Used in Swimming Pools, to include information regarding the potential for oxidizers to corrode metals such as sprinkler components and reference NFPA 13 Standard for the Installation of Sprinklers.
From Bio-Lab Inc. Conyers Fire and Chemical Release, September 29, 2024
International Code Council (ICC) · 5 open
- 2002-03-I-TX-3Open - Acceptable Response or Alternate Response
Revise the International Fire Code to address the following issues: For facilities that are not staffed around the clock, specify circumstances where automatic fire detection is needed. Narrow exemptions for Class IIIB liquids. Expand fire protection analysis requirements to include all areas of a facility where there may be flammable or combustible fire risks.
From Third Coast Industries Petroleum Products Facility Fire, May 1, 2002
- 2007-03-I-MA-11Open - Acceptable Response or Alternate Response
Revise the International Fire Code: Chapter 20: - Specifically include "printing inks" in the definition of "organic coating." - Define equipment specifically discussed in the standard, such as open and closed kettles. - Require heated tanks and vessels containing flammable and combustible liquids to have equipment to prevent overheating, such as: devices to stop the heating process if the temperature exceeds the safe operating limits; devices to stop the heating process if the flammable vapor control equipment malfunctions (e.g., building ventilation system or heated tank vent); and a heating medium that is unable to heat the tank above safe operating temperatures. Chapters 20, 27, and 34: -Define "open", "closed", and "sealed and vented" process tanks. -Define "non-listed" process tanks. -Prohibit heating flammable and combustible liquids above their flashpoints in tanks inside buildings unless the tanks are sealed and vented to the building exterior.
From CAI / Arnel Chemical Plant Explosion, November 22, 2006
- 2013-02-I-TX-6Open - Awaiting Response or Evaluation/Approval of Response
In a subsequent edition of the International Fire Code, develop a chapter or a separate section under Chapter 50 (“Hazardous Materials”) or Chapter 63 (“Oxidizers, Oxidizing Gases and Oxidizing Cryogenic Fluids”) that includes the following requirements for the storage and handling of ammonium nitrate (AN): a. Require automatic fire detection and suppression systems in existing buildings constructed of combustible materials b. Provide ventilation requirements in accordance with the International Mechanical Code to prevent the accumulation of off-gases produced during AN decomposition c. Provide smoke and heat vents to remove heat from AN during fire situations d. Establish minimum safe separation distances between AN and combustible materials to avoid contamination in the event of fire. e. Prohibit the use of combustible materials of construction.
From West Fertilizer Explosion and Fire, April 17, 2013
- 2021-01-I-TN-9Open - Awaiting Response or Evaluation/Approval of Response
Amend the International Building Code (IBC) to address conditions that may require multiple means of egress from elevated equipment platforms used for accessing equipment containing materials that pose physical and health hazards, such as the one used at Wacker in this incident. Specify the minimum number of egress points to increase the likelihood of worker escape in the event of a hazardous material release.
From Wacker Polysilicon Chemical Release, November 13, 2020
- 2021-03-I-GA-12Open - Acceptable Response or Alternate Response
Update the International Fire Code to: a) require the use of atmospheric monitoring with cryogenic asphyxiants in accordance with industry guidance such as is contained in CGA P-76 Hazards of Oxygen-Deficient Atmospheres and CGA P-12 Safe Handling of Cryogenic Liquids in addition to CGA P-18 Standard for Bulk Inert Gas Systems; and, b) include guidance on the adequate safe location of manual shutoff valves and devices such as emergency push buttons used to activate remotely operated emergency isolation valves (ROEIVs) in cryogenic fluid service. At a minimum this guidance should be harmonized with the requirements of ISO 13850 Safety of machinery – Emergency stop function – Principles for design.
From Foundation Food Group Fatal Chemical Release, January 28, 2021
U.S. Steel Clairton Coke Works · 5 open
- 2025-03-I-PA-1Open - Awaiting Response or Evaluation/Approval of Response
Conduct a siting evaluation for all occupied and potentially occupied buildings at the Clairton Coke Works facility. Utilize the guidance contained in the Center for Chemical Process Safety’s Guidelines for Evaluating Process Plant Buildings for External Explosions, Fires, and Toxic Releases, the American Petroleum Institute’s Recommended Practices 752, 753, and 756, and other industry good practice guidance documents.
From United States Steel Corporation Clairton Plant Coke Oven Explosion, August 11, 2025
- 2025-03-I-PA-2Open - Awaiting Response or Evaluation/Approval of Response
Using the results from the evaluation performed in 2025-03-I-PA-R1, ensure that all documented facility siting hazards are mitigated in accordance with the guiding principles contained in the American Petroleum Institute’s Recommended Practices 752, 753, and 756.
From United States Steel Corporation Clairton Plant Coke Oven Explosion, August 11, 2025
- 2025-03-I-PA-3Open - Awaiting Response or Evaluation/Approval of Response
Develop a written procedure in accordance with industry guidance such as NFPA 56 Standard for Fire and Explosion Prevention During Cleaning and Purging of Flammable Gas Piping Systems, for washing valve seats with pressurized water. Ensure that the procedure includes steps and other controls, including overpressure protection, to minimize the hazards of the operation. Ensure that workers who will or might perform the operation are involved in the development of the procedure and are trained on the procedure.
From United States Steel Corporation Clairton Plant Coke Oven Explosion, August 11, 2025
- 2025-03-I-PA-4Open - Awaiting Response or Evaluation/Approval of Response
Conduct a hazard analysis or safety validation of the written valve washing procedure in accordance with NFPA 56 Standard for Fire and Explosion Prevention During Cleaning and Purging of Flammable Gas Piping Systems. Ensure that workers who will or might perform the operation are involved in the analysis or validation.
From United States Steel Corporation Clairton Plant Coke Oven Explosion, August 11, 2025
- 2025-03-I-PA-5Open - Awaiting Response or Evaluation/Approval of Response
Develop a comprehensive process safety management system, incorporating guidance from the Center for Chemical Process Safety’s Guidelines for Risk Based Process Safety and other industry good practice guidance publications, and apply it to all coke oven gas processes at the Clairton facility.
From United States Steel Corporation Clairton Plant Coke Oven Explosion, August 11, 2025
Yenkin-Majestic/OPC Polymers · 5 open
- 2021-04-I-OH-1Open - Unacceptable Response/No Response Received
Update mechanical integrity procedures for all process vessels in highly hazardous chemicals service, including pressure vessels not exceeding 15 psig, to adopt alteration guidance in API 510 Pressure Vessel Inspection Code or Part 3 of the National Board Inspection Code.
From Yenkin-Majestic Resin Plant Vapor Cloud Explosion and Fire, April 8, 2021
- 2021-04-I-OH-2Open - Unacceptable Response/No Response Received
Assess and document applicable design, construction, and alteration standards for all pressure vessels in highly hazardous chemicals service in new resin plant designs, including pressure vessels not exceeding 15 psig. At a minimum, adopt PIP VESLP001 Low-Pressure, Welded Vessel Specification as design and construction guidance for pressure vessels not exceeding 15 psig. Implement a program to assess the pressure vessels against updated applicable recognized and generally accepted good engineering practices, such as those published by API, ASME, PIP, and other organizations, at least once every five years, and address the gaps identified. Develop and implement written procedures to document and maintain records of (i) all inspections of, (ii) all alterations to, and (iii) all maintenance and repairs on all pressure vessels in highly hazardous chemicals service.
From Yenkin-Majestic Resin Plant Vapor Cloud Explosion and Fire, April 8, 2021
- 2021-04-I-OH-3Open - Unacceptable Response/No Response Received
Demonstrate the use of prevention through design using the hierarchy of controls in future resin plant designs. Specifically, prioritize inherently safer design and engineering controls to prevent process safety events. Refer to sources such as Safety Instrumented Systems: A Life-Cycle Approach by P. Gruhn and S. Lucchini, Human Error in Process Plant Design and Operations – A Practitioner’s Guide by J. Robert Taylor, Guidelines for Preventing Human Error in Process Safety by the Center for Chemical Process Safety (CCPS), Guidelines for Inherently Safer Chemical Processes – A Life Cycle Approach by the CCPS, and Guidelines for Risk Based Process Safety by the CCPS for guidance. Demonstration could include documentation of conceptual design safety reviews, hazard analysis and risk assessments of detailed project designs, and a plan to address the recommendations to control the hazards.
From Yenkin-Majestic Resin Plant Vapor Cloud Explosion and Fire, April 8, 2021
- 2021-04-I-OH-4Open - Unacceptable Response/No Response Received
Identify and document all equipment that could release flammable materials and install LEL detectors in accordance with sources and guidance such as Guidelines for Engineering Design for Process Safety by the Center for Chemical Process Safety and Explosion Hazards in the Process Industries by Rolf K. Eckhoff. Ensure that detection of hazardous conditions automatically triggers both visual and audible alarms to alert plant personnel of the hazard. Develop and implement employee training on actions to take, such as prompt evacuation, when such alarms are activated.
From Yenkin-Majestic Resin Plant Vapor Cloud Explosion and Fire, April 8, 2021
- 2021-04-I-OH-5Open - Unacceptable Response/No Response Received
Develop and implement requirements for personnel to wear flame-resistant uniforms in all operating areas that process flammable chemicals. Update employee training material to include the requirement for and purpose of PPE use.
From Yenkin-Majestic Resin Plant Vapor Cloud Explosion and Fire, April 8, 2021
American Society of Mechanical Engineers (ASME) · 4 open
- 2012-03-I-CA-32Open - Acceptable Response or Alternate Response
Revise ASME PCC-2-2011: Repair of Pressure Equipment and Piping to require users to follow the minimum process fluid leak response requirements established in API RP 2001: Fire Protection in Refineries, developed in response to recommendation 2012-03-I-CA-R31, before conducting process fluid leak repair.
From Chevron Richmond Refinery Fire, August 6, 2012
- 2021-04-I-OH-7Open - Awaiting Response or Evaluation/Approval of Response
Assist API in developing design, construction, and alteration guidance for low-pressure vessels in flammable and other highly hazardous chemicals service not exceeding an internal pressure of 15 psig. If any new design and construction guidance is specifically developed for pressure vessels in flammable and other highly hazardous chemicals service not exceeding an internal pressure of 15 psig, reference the design and construction guidance in the Section VIII, Division 1 of the ASME Boiler and Pressure Vessel Code (BPVC).
From Yenkin-Majestic Resin Plant Vapor Cloud Explosion and Fire, April 8, 2021
- 2021-05-I-TX-4Open - Awaiting Response or Evaluation/Approval of Response
Revise American Society of Mechanical Engineers (ASME) Standard B16.34 Valves—Flanged, Threaded, and Welding End as follows: a. For existing plug valves, require facilities to clearly mark all pressure-retaining components (for example, with paint, accompanying warning signs, etc.). Work with American Petroleum Institute (API) and the Valve Manufacturers Association of America (VMA) to ensure a consistent methodology is specified across both API and ASME standards. b. Require that new plug valves be designed, consistent with Prevention through Design principles, to prevent the inadvertent removal of pressure-retaining components when removing the actuator or gearbox. Evaluate past plug valve incidents, and the associated plug valve designs involved in those incidents, when formulating a new plug valve design. Work with API and VMA to ensure a consistent methodology is specified across both API and ASME standards.
From LyondellBasell La Porte Fatal Chemical Release, July 27, 2021
- 2024-05-I-TX-4Open - Awaiting Response or Evaluation/Approval of Response
Develop written guidelines for marking equipment for opening. The guidelines should define a standard practice for equipment marking that includes clear identifiers of the area to be opened and means to remove the markings at the conclusion of the work.
From PEMEX Deer Park Chemical Release, October 10, 2024
HEF Groupe · 4 open
- 2024-01-I-TN-4Open - Acceptable Response or Alternate Response
Include physical, protective barriers as part of the standard design for liquid nitriding processes. These protective barriers shall be intended to isolate employees from molten salt releases.
From TS USA Molten Salt Eruption, May 30, 2024
- 2024-01-I-TN-5Open - Acceptable Response or Alternate Response
Develop a safety management system that incorporates industry guidance and includes, but is not limited to: a. A hazard analysis program for assessing the nitriding process. The program shall incorporate industry guidance, such as the Center for Chemical Process Safety’s (CCPS) Guidelines for Risk-Based Process Safety, the National Fire Protection Association’s (NFPA) Standard for Ovens and Furnaces, and ASM International’s Handbook. The program shall apply to new and existing parts, assess parts for accumulation hazards and sealed cavities, and include non-routine tasks such as reprocessing unsatisfactory parts. b. Written operating procedures for the nitriding process. The procedures shall be based on the information gathered from the hazard analysis program. The procedures shall incorporate industry guidance, such as the Center for Chemical Process Safety’s (CCPS) Guidelines for Risk-Based Process Safety and the CCPS’s Guidelines for Writing Effective Operating and Maintenance Procedures. c. A training program, including written materials, for the employees involved in the nitriding process. This program shall be based on the nitriding facility’s operating procedures and other relevant information from the hazard analysis program. The program shall incorporate industry guidance, such as the Center for Chemical Process Safety’s (CCPS) Guidelines for Risk-Based Process Safety. d. An incident investigation program. This program shall include requirements for performing causal analysis, producing written reports, and communicating findings and corrective actions throughout the entire HEF Groupe organization. The program shall incorporate industry guidance, such as the Center for Chemical Process Safety’s (CCPS) Guidelines for Risk-Based Process Safety and the CCPS’s Guidelines for Investigating Process Safety Incidents.
From TS USA Molten Salt Eruption, May 30, 2024
- 2024-01-I-TN-6Open - Acceptable Response or Alternate Response
Develop and implement an effective and comprehensive Knowledge Management program for sharing knowledge throughout the HEF Groupe organization. Knowledge shall include all information from audits, hazard analyses, and incident investigations, including causal analyses and corrective actions recommended and taken. This program shall incorporate industry guidance, such as the Center for Chemical Process Safety’s (CCPS) Guidelines for Process Safety Knowledge Management.
From TS USA Molten Salt Eruption, May 30, 2024
- 2024-01-I-TN-7Open - Acceptable Response or Alternate Response
Develop and implement a comprehensive and effective Corporate Governance program. This program shall include regular audits of subordinate facilities throughout the organization, with tracking and accountability for implementation of all recommendations and corrective actions identified in the audits. Facility adherence to the safety management system recommended above shall be evaluated during the audits. The program shall require documentation of audit findings, prompt responses to deficiencies, development of corrective actions, and implementation of the corrective actions throughout the organization. This program shall incorporate industry guidance, such as the Center for Chemical Process Safety’s (CCPS) Guidelines for Implementing Process Safety Management.
From TS USA Molten Salt Eruption, May 30, 2024
KIK Consumer Products · 4 open
- 2024-04-I-GA-1Open - Awaiting Response or Evaluation/Approval of Response
Develop and implement a corporate standard for the storage (including storage configuration) and handling of bulk pool-treatment chemicals, including but not limited to chlorinated isocyanurates and BCDMH, at facilities in the company’s Pool Division. At a minimum, the standard shall ensure compliance with NFPA 400 Hazardous Materials Code (for storage, construction, and other requirements) and NFPA 13 Standard for the Installation of Sprinkler Systems (for corrosion resistance and other requirements), and that any non-compliance is addressed within a specified timeframe. The incident history of KIK Consumer Product facilities, including the Bio-Lab Lake Charles and Bio-Lab Conyers sites, shall be used to guide the development of the standard.
From Bio-Lab Inc. Conyers Fire and Chemical Release, September 29, 2024
- 2024-04-I-GA-2Open - Awaiting Response or Evaluation/Approval of Response
Develop and implement a corporate standard that requires an assessment of all KIK Consumer Products / Bio-Lab, Inc. third-party facilities that manufacture and/or store bulk pool-treatment chemicals, including but not limited to chlorinated isocyanurates and BCDMH, to ensure compliance with NFPA 400 Hazardous Materials Code (for storage, construction, and other requirements) and NFPA 13 Standard for the Installation of Sprinkler Systems (for corrosion resistance and other requirements). The standard shall ensure that any non-compliance with NFPA 400 and NFPA 13 is appropriately addressed prior to operations. The standard shall ensure that existing third-party facilities that manufacture and/or store bulk chlorinated isocyanurates and BCDMH are assessed for compliance with NFPA 400 and NFPA 13, and that any non-compliance is addressed within a specified timeframe. The incident history of KIK Consumer Product facilities, including the Bio-Lab Lake Charles and Bio-Lab Conyers sites, shall be used to guide the development of the standards.
From Bio-Lab Inc. Conyers Fire and Chemical Release, September 29, 2024
- 2024-04-I-GA-3Open - Awaiting Response or Evaluation/Approval of Response
Contract a third party to audit the implementation of the PSM Lite program within KIK’s Pool Division, including all facilities that handle and/or store bulk pool-treatment chemicals, including but not limited to chlorinated isocyanurates and BCDMH. Address all identified deficiencies resulting from the audit within a specified timeframe.
From Bio-Lab Inc. Conyers Fire and Chemical Release, September 29, 2024
- 2024-04-I-GA-4Open - Awaiting Response or Evaluation/Approval of Response
Contract a third party to audit the implementation of the corporate standards developed in recommendations 2024-04-I-GA-R1 and 2024-04-I-GA-R2 at KIK Consumer Products / Bio-Lab, Inc. Pool Division facilities and third-party facilities that manufacture and/or store bulk pool-treatment chemicals. Address all identified deficiencies resulting from the audit within a specified timeframe.
From Bio-Lab Inc. Conyers Fire and Chemical Release, September 29, 2024
Clearon Corporation · 3 open
- 2021-02-I-WV-5Open - Unacceptable Response/No Response Received
Develop and implement a comprehensive process knowledge management program or evaluate and revise existing process safety management procedures to ensure consistency with industry guidance publications such as the Center for Chemical Process Safety’s Guidelines for Risk Based Process Safety. The program should: a) assign specific responsibilities for compiling content and maintaining robust process technology and safety information packages that incorporate relevant knowledge for all hazardous processes and substances operated, manufactured, and/or handled by Clearon Corporation; b) ensure that key process personnel are aware of critical reactive chemistry information, including thermal stability and calorimetry data, chemical compatibility information, and descriptions of any past reactive incidents and safety studies involving the materials; and c) define procedures for the transmittal of such information to toll manufacturers.
From Optima Belle Explosion and Fire, December 8, 2020
- 2021-02-I-WV-7Open - Unacceptable Response/No Response Received
Develop and implement a written program for tolling process design and equipment selection using resources such as the Center for Chemical Process Safety’s Guidelines for Process Safety in Outsourced Manufacturing Operations and Guidelines for Risk Based Process Safety to ensure that: a) equipment design basis is adequate for any new tolling process or product; and b) safeguards and ancillary equipment are considered and adequately designed, installed, and function as designed and required.
From Optima Belle Explosion and Fire, December 8, 2020
- 2021-02-I-WV-8Open - Unacceptable Response/No Response Received
Develop and implement a formalized program for the development of toll manufacturing agreements using resources such as the Center for Chemical Process Safety’s Guidelines for Process Safety in Outsourced Manufacturing Operations and Guidelines for Risk Based Process Safety. Ensure that the program provides for the following: a) Identification of roles and responsibilities of all parties, including the client, toller, and any third-party technical service providers, for all phases of a proposed arrangement; b) Evaluation of equipment requirements/specifications to ensure that they are adequate for the intended operation; and c) Participation by all parties in tolling process development, including process hazards analysis and emergency planning, and appropriate stages of the pre-planning, pre-startup, and production phases.
From Optima Belle Explosion and Fire, December 8, 2020
Cuisine Solutions Inc. Sterling Site · 3 open
- 2024-03-I-VA-3Open - Awaiting Response or Evaluation/Approval of Response
Reduce the likelihood or mitigate the consequences of liquid or two-phase atmospheric discharges from the ammonia refrigeration emergency pressure relief system at the Sterling plant. At a minimum: a. Identify liquid or two-phase release scenarios, particularly for horizontal surge drums and other vessels containing saturated liquid with little vapor space; b. Implement engineering controls to reduce the likelihood of high liquid level, overfill, or boiling overpressure scenarios; c. Implement engineering controls to mitigate the consequences of these scenarios where their likelihood cannot be acceptably reduced, such as through emergency pressure control systems, atmospheric knockout drums, or automatic shutdown systems; and d. Contract a competent third party to audit the pressure relief systems. The audit should ensure that (i) all relevant relief scenarios have been identified, (ii) preventive and mitigative engineering controls adequately address the hazards, and (iii) engineering controls are maintained in such a way that they function properly when required.
From Cuisine Solutions Ammonia Release, July 31, 2024
- 2024-03-I-VA-5Open - Acceptable Response or Alternate Response
Update the Cuisine Solutions Sterling site’s Emergency Action Plan using guidance such as the IIAR’s Critical Task Guidance for Ammonia Refrigeration System Emergency Planning. At a minimum, the updated plan should: a. Address indoor and outdoor ammonia releases separately, including the distinct alarms and responses to them; b. Clearly specify appropriate evacuation routes and muster points, including alternates; c. Provide guidance for using windsocks to remain upwind of a release during evacuation; d. Implement shelter-in-place strategies, emergency protective equipment, and emergency shutdowns, as appropriate; and e. Include requirements to conduct annual ammonia release drills that include all onsite personnel (including corporate employees). The annual drills should include separate indoor and outdoor ammonia release scenarios and address the use of windsocks to assist with determining evacuation routes, alternate evacuation routes, muster points, and consideration for the decision to shelter-in-place. Additionally, the drills should exercise each evacuation alarm, emergency protective equipment, and emergency shutdowns, where appropriate.
From Cuisine Solutions Ammonia Release, July 31, 2024
- 2024-03-I-VA-6Open - Acceptable Response or Alternate Response
Add an alarm or alarms specific to ammonia releases, so that workers can properly respond to a release. The alarm response should be documented in the updated Emergency Action Plan, and may include multiple distinct alarms and responses, such as one for shelter-in-place and one for evacuation.
From Cuisine Solutions Ammonia Release, July 31, 2024
Honeywell International, Inc. · 3 open
- 2023-02-I-LA-1Open - Acceptable Response or Alternate Response
Perform a comprehensive third-party audit of the Geismar facility’s process safety and allied management systems as soon as practicable. The audit shall: A. Be performed or led by an individual, firm, or team meeting the requirements outlined in paragraphs (b), (c), and (d) of Appendix E of this report. B. Evaluate compliance with applicable federal standards (40 C.F.R. § 68 and 29 C.F.R. § 1910.119). In particular, the audit shall include the required elements that contributed to these incidents, including but not limited to: 1. management of change; 2. mechanical integrity; 3. quality assurance; 4. pre-startup safety reviews; 5. operating procedures; and 6. contractor management. C. Evaluate other internal management systems that contributed to these incidents. In particular, the audit shall include but not be limited to: 1. management of organizational and personnel change; 2. management of safety-related capital projects; 3. organizational resilience; and 4. safe work practices including, but not limited to: a. work permitting; b. preparation of equipment for maintenance; c. control of hazardous energy; d. line break safety; and e. personal protective equipment. D. Use the Center for Chemical Process Safety’s Guidelines for Auditing Process Safety Management Systems as guidance to verify both the suitability of these systems and their effective, consistent implementation and performance. E. Result in the development of a comprehensive report meeting the requirements outlined in paragraphs (e) and (f) of Appendix E of this report. If any findings are rejected, the rationale for and documentation supporting the merit of the rejection shall be included. The report in its entirety shall be made available to the Honeywell workforce at the Geismar, Louisiana; Baton Rouge, Louisiana; and Metropolis, Illinois, sites.
From Honeywell Geismar Chlorine and Hydrogen Fluoride Releases, January 23, 2023
- 2023-02-I-LA-2Open - Acceptable Response or Alternate Response
Require periodic reporting updates from the Geismar site regarding the closure of the audit findings. The periodic updates shall continue until all audit findings are fully closed.
From Honeywell Geismar Chlorine and Hydrogen Fluoride Releases, January 23, 2023
- 2023-02-I-LA-3Open - Acceptable Response or Alternate Response
Perform a Safer Technologies and Alternatives Analysis (STAA) for the Honeywell Geismar HFC-245fa unit. The STAA shall meet the requirements outlined in paragraphs (a) and (b) of Appendix F of this report.
From Honeywell Geismar Chlorine and Hydrogen Fluoride Releases, January 23, 2023
Intercontinental Terminals Company, LLC · 3 open
- 2019-01-I-TX-2Open - Acceptable Response or Alternate Response
Develop and implement a condition monitoring program for all pumps in highly hazardous chemical service at the ITC Deer Park terminal. Ensure that condition monitoring equipment is programmed with control limits, including but not limited to vibration, consistent with ANSI/HI 9.6.9.-2018, that trigger alarms when control limits are exceeded, and that operating procedures and training reflect the appropriate actions to take when an alarm is triggered.
From Intercontinental Terminals Company (ITC) Tank Fire, March 17, 2019
- 2019-01-I-TX-4Open - Acceptable Response or Alternate Response
Install remotely operated emergency isolation valves configured to “Fail-Closed” for all atmospheric storage tanks that contain highly hazardous chemicals or liquids with a flammability rating of NFPA-3 or higher at the ITC Deer Park terminal.
From Intercontinental Terminals Company (ITC) Tank Fire, March 17, 2019
- 2019-01-I-TX-5Open - Acceptable Response or Alternate Response
Conduct an evaluation of the design of all new and existing tank farms at the ITC Deer Park terminal against the applicable sections of the Third Edition of API STD 2610, Design, Construction, Operation, Maintenance, and Inspection of Terminal and Tank Facilities and the 2021 Edition of NFPA 30, Flammable and Combustible Liquids Code. At a minimum the evaluation should include, but is not limited to the following sections of API STD 2610: Section 4 Site Selection and Spacing Requirements Section 7 Fire Prevention and Protection Section 8.1 Aboveground Petroleum Storage Tanks Section 9 Dikes and Berms Section 10 Pipe, Valves, Pumps, and Piping Systems Section 11 Loading, Unloading, and Product Transfer Facilities and the following chapters of NFPA 30: Chapter 21 Storage of Ignitible (Flammable or Combustible) Liquids in Tanks – Requirements for All Storage Tanks and Chapter 22 Storage of Ignitible (Flammable or Combustible) Liquids in Tanks – Aboveground Storage Tanks The evaluation should identify additional engineering controls needed to address minimal tank spacing, subdivisions between tanks, and placement of process equipment in containment areas. In addition, the evaluation should assess the adequacy of the containment wall and drainage system designs, accounting for the impact of firefighting activities, including the application of firewater and foam on these systems. Develop and implement recommendations based on findings from the evaluation.
From Intercontinental Terminals Company (ITC) Tank Fire, March 17, 2019
Marathon Martinez Renewables · 3 open
- 2024-01-I-CA-2Open - Acceptable Response or Alternate Response
For the fired heater involved in the incident, after Marathon Petroleum Corporation’s “Process Heater Not-to-Exceed (NTE) Limits and Alarms” standard is updated according to 2024-01-I-CA-R5, implement tube metal temperature alarming consistent with corporate guidance to alert operators when safe operating limits are exceeded and to specify predetermined response actions, such as shutting down the fired heater remotely. The predetermined response actions must include actions that specify when to stop troubleshooting and remove personnel from the vicinity of the fired heater.
From Marathon Martinez Renewable Fuels Fire, November 19, 2023
- 2024-01-I-CA-3Open - Acceptable Response or Alternate Response
Implement changes to improve Walk the Line performance at the Martinez facility by ensuring that the facility’s practices are consistent with tools in the AFPM Safety Portal and guidance in Marathon Petroleum Corporation’s refining reference document titled Operations Excellence. At a minimum: Require that operator field walkdowns ensure that valves are correctly aligned before all unit startup activities from planned or unplanned shutdowns, such as those due to non-normal operations, emergencies, turnarounds, and major maintenance; Improve policies and practices for communications among and between shifts to ensure that operators understand abnormal line-ups in their units; and Reinforce Walk the Line concepts, including the expectation for only trained operators to control valve line-ups at their units, through training for all levels of management in the Operations department.
From Marathon Martinez Renewable Fuels Fire, November 19, 2023
- 2024-01-I-CA-4Open - Acceptable Response or Alternate Response
Complete a comprehensive gap assessment of the Martinez facility against Marathon Petroleum Corporation policies. At a minimum, address the following policies: a. Operating Limits; b. Process Hazard Analysis; and c. PSM/RMP Refining Operating Procedures. Develop and implement action items to effectively address findings from the assessment.
From Marathon Martinez Renewable Fuels Fire, November 19, 2023
Marathon Petroleum Corporation · 3 open
- 2024-01-I-CA-5Open - Acceptable Response or Alternate Response
Update the corporate “Process Heater Not-to-Exceed (NTE) Limits and Alarms” standard with tube metal temperature alarming guidance to alert operators when safe operating limits are exceeded and to specify predetermined response actions, such as shutting down the fired heater remotely. The predetermined response actions must include actions that specify when to stop troubleshooting and remove personnel from the vicinity of the fired heater.
From Marathon Martinez Renewable Fuels Fire, November 19, 2023
- 2024-01-I-CA-6Open - Acceptable Response or Alternate Response
Update the corporate “Heater Application Standard” with the following requirements: Requirements for protecting fired heaters from low process flow where process piping diverges downstream of a flow meter. Requirements may include achieving proof of flow to the heater through valve position indicators and interlocks on branch connections downstream of flow meters to prevent backflow, reverse flow, or other diverted flow scenarios that could defeat the safety instrumented system; and Engineering safeguard requirements to detect and prevent afterburning in fired heaters. The safeguards may include the use of instrumentation such as combustibles measurements, flame detectors, and/or thermocouples that measure tube metal, flue gas, and process fluid temperatures. The safeguards shall be capable of being monitored from the control room.
From Marathon Martinez Renewable Fuels Fire, November 19, 2023
- 2024-01-I-CA-7Open - Acceptable Response or Alternate Response
Confirm the results of the Martinez facility’s comprehensive gap assessment required in 2024-01-I-CA-R4. Upon completion, conduct an Operations Excellence full assessment on the Martinez facility. Develop and implement action items to effectively address findings from the assessment.
From Marathon Martinez Renewable Fuels Fire, November 19, 2023
PEMEX Deer Park · 3 open
- 2024-05-I-TX-1Open - Awaiting Response or Evaluation/Approval of Response
Label all piping in ARU6 and ARU7 in accordance with ANSI/ASME A 13.1 Scheme for the identification of Piping Systems.
From PEMEX Deer Park Chemical Release, October 10, 2024
- 2024-05-I-TX-2Open - Awaiting Response or Evaluation/Approval of Response
Develop procedures to ensure that any craftworkers introduced to or removed from a unit in Positive Isolation Status receive instructions that define the hazards, safeguards, and requirements of the unit associated with the work. The procedures should require each craftworker to receive clear communication on the identified hazards, control measures, and all other requirements before commencing work in a new area.
From PEMEX Deer Park Chemical Release, October 10, 2024
- 2024-05-I-TX-3Open - Awaiting Response or Evaluation/Approval of Response
Establish a conduct of operations system that establishes and enforces behavioral and performance metrics in accordance with CCPS’s Conduct of Operations and Operational Discipline. The system should include: a) the management commitment to process safety, b) employee input on policies and procedures, c) methods to ensure that policies and procedures can be effectively followed, to include, at a minimum: 1) permitting, 2) equipment marking, and 3) energy isolation procedures, and d) regular audits to verify adherence to conduct of operations metrics, to include, at a minimum: 1) performance expectations, 2) training, 3) management visibility, 4) leadership by example, and 5) worker knowledge and awareness.
From PEMEX Deer Park Chemical Release, October 10, 2024
Compressed Gas Association (CGA) · 2 open
- 2021-03-I-GA-9Open - Awaiting Response or Evaluation/Approval of Response
Develop a comprehensive standard for the safe storage, handling, and use of liquid nitrogen in stationary applications, comparable to the guidance presented in CGA G-6.5 Standard for Small Stationary Insulated Carbon Dioxide Systems. At a minimum, the standard should include: a) requirements for and guidance on the location, the maintenance, and the functional testing of atmospheric monitoring devices; b) requirements for visible and audible alarm indication distinct from the building’s fire alarm system and at a continuously attended location; c) guidance on the design, function, periodic maintenance and testing, and location of room and emergency ventilation systems; and, d) requirements for and guidance on the location of emergency shutdown devices including E-stops.
From Foundation Food Group Fatal Chemical Release, January 28, 2021
- 2021-03-I-GA-10Open - Awaiting Response or Evaluation/Approval of Response
Update P-76 Hazards of Oxygen-Deficient Atmospheres. At a minimum, the updated standard should: a) require that atmospheric monitoring systems shall be utilized with processes, equipment, and piping systems capable of producing oxygen-deficient atmospheres; b) require that atmospheric monitoring systems provide both visible and audible alarm indication distinct from a building’s fire alarm system and at a continuously attended location; c) require that processes, equipment, and piping systems capable of producing oxygen-deficient atmospheres shall be equipped with remotely operated emergency isolation valves (ROEIVs); and d) include guidance on the adequate safe location of emergency stop devices. At a minimum this guidance should be harmonized with the requirements of ISO 13850 Safety of machinery – Emergency stop function – Principles for design. As necessary, augment the general guidance of ISO 13850 with guidance specific to processes, equipment, and piping using cryogenic asphyxiants and inert gases.
From Foundation Food Group Fatal Chemical Release, January 28, 2021
Governor and Legislature of the State of Washington · 2 open
- 2010-08-I-WA-6Open - Acceptable Response or Alternate Response
Establish a well-funded, well-staffed, technically qualified regulator with a compensation system to ensure the Washington Department of Labor and Industries regulator has the ability to attract and retain a sufficient number of employees with the necessary skills and experience to ensure regulator technical qualifications. Periodically conduct a market analysis and benchmarking review to ensure the compensation system remains competitive with Washington petroleum refineries.
From Tesoro Anacortes Refinery Fatal Explosion and Fire, April 2, 2010
- 2010-08-I-WA-7Open - Acceptable Response or Alternate Response
Work with the regulator, the petroleum refining industry, labor, and other relevant stakeholders in the state of Washington to develop and implement a system that collects, tracks, and analyzes process safety leading and lagging indicators from operators and contractors to promote continuous process safety improvements. At a minimum, this program shall: a. Require the use of leading and lagging process safety indicators to actively monitor the effectiveness of process safety management systems and safeguards for major accident prevention. Include leading and lagging indicators that are measureable, actionable, and standardized. Include indicators that measure safety culture, such as incident reporting and action item implementation culture. Require that the reported data be used for continuous process safety improvement and accident prevention; b. Analyze data to identify trends and poor performer s and publish annual reports with the data at facility and corporate levels; c. Require companies to publicly report required indicators annually at facility and corporate levels; d. Use process safety indicators (1) to drive continuous improvement for major accident prevention by using the data to identify industry and facility safety trends and deficiencies and (2) to determine appropriate allocation of regulator resources and inspections; and e. Be periodically updated to incorporate new learning from world-wide industry improvements in order to drive continuous major accident process safety improvements in Washington.
From Tesoro Anacortes Refinery Fatal Explosion and Fire, April 2, 2010
International Institute of All-Natural Refrigeration (IIAR) · 2 open
- 2024-03-I-VA-1Open - Awaiting Response or Evaluation/Approval of Response
Update ANSI/IIAR 2 to include guidance for preventing or mitigating liquid or two-phase atmospheric discharges from emergency pressure relief systems, such as the guidance in API Standard 521, Pressure-relieving and Depressuring Systems. At a minimum, the guidance should: a. Identify at-risk scenarios such as horizontal surge vessels and other vessels containing saturated liquid with little vapor space; b. Address design considerations and controls to reduce the likelihood of identified scenarios leading to overpressure or equipment failure and ensure vapor-liquid disengagement (the separation of vapor from liquid) during pressure relief for identified scenarios; and c. Require mitigative safeguards in cases where vapor-liquid disengagement during pressure relief cannot be reliably ensured. This should also include alternative disposal systems where applicable.
From Cuisine Solutions Ammonia Release, July 31, 2024
- 2024-03-I-VA-2Open - Awaiting Response or Evaluation/Approval of Response
Update ANSI/IIAR 2 to include a requirement to assess whether emergency pressure relief devices discharge to a safe location, such as with a dispersion analysis.
From Cuisine Solutions Ammonia Release, July 31, 2024
International Technical Caramel Association (ITCA) · 2 open
- 2024-06-I-KY-9Open - Awaiting Response or Evaluation/Approval of Response
Publish a technical safety bulletin for caramel coloring manufacturing that encourages caramel color manufacturers to ensure known hazards, including sugar ingredient decomposition, are addressed. Emphasize the importance of obtaining information on calorimetric properties of sugar ingredients and ensuring appropriately sized emergency pressure relief systems to safely vent pressure and gases that could be produced by sugar ingredient decomposition reactions, as well as other overpressure scenarios identified in hazard analyses. Refer caramel color manufacturers to the CSB’s investigation report for additional details. Recommend in the technical safety bulletin that caramel coloring manufacturers implement, as appropriate, process safety management systems that are in alignment with local requirements and chemical industry good practice guidance, such as the Center for Chemical Process Safety Guidelines for Risk Based Process Safety, Essential Practices for Managing Chemical Reactivity Hazards, and Guidelines for Implementing Process Safety Management.
From Givaudan Sense Colour Explosion, November 12, 2024
- 2024-06-I-KY-10Open - Awaiting Response or Evaluation/Approval of Response
Alert association members that manufacture caramel coloring of the November 12, 2024, Givaudan incident and its causes, including but not limited to the sugar ingredient decomposition reaction that led to Reactor 6’s rupture.
From Givaudan Sense Colour Explosion, November 12, 2024
Shell Polymers Monaca · 2 open
- 2025-05-I-PA-1Open - Awaiting Response or Evaluation/Approval of Response
Review the Shell Polymers Monaca Ethane Cracking Unit process hazard analysis to identify process deviations that are addressed solely with administrative controls. Implement an inherently safer design or an engineered control for any scenario identified that could result in a fatality, serious injury, or substantial property damage.
From Shell Polymers Furnace Explosion and Fire, June 4, 2025
- 2025-05-I-PA-2Open - Awaiting Response or Evaluation/Approval of Response
Based on licensor input and good industry practices, such as ANSI/ISA-61511-2-2018 / IEC 61511-2:2016, Functional Safety – Safety Instrumented Systems for the Process Industry Sector – Part 2: Guidelines for the application of IEC 61511-1:2016 and Part 3: Guidance for the Determination of the Required Safety Integrity Levels, implement and maintain an engineered control to prevent backflow of cracked gas into a furnace during all modes of furnace operation.
From Shell Polymers Furnace Explosion and Fire, June 4, 2025
Techniques Surfaces USA (TS USA) · 2 open
- 2024-01-I-TN-1Open - Acceptable Response or Alternate Response
Implement physical, protective barriers around the molten salt baths that isolate employees from hazardous releases at all locations that perform liquid nitriding.
From TS USA Molten Salt Eruption, May 30, 2024
- 2024-01-I-TN-2Open - Acceptable Response or Alternate Response
Develop a safety management system that incorporates industry guidance and includes, but is not limited to: a. A hazard analysis program for assessing the nitriding process. The program shall incorporate industry guidance, such as the Center for Chemical Process Safety’s (CCPS) Guidelines for Risk-Based Process Safety, the National Fire Protection Association’s (NFPA) Standard for Ovens and Furnaces, and ASM International’s Handbook. The program shall apply to new and existing parts, assess parts for accumulation hazards and sealed cavities, and include non-routine tasks such as reprocessing unsatisfactory parts. b. Written operating procedures for the nitriding process. The procedures shall be based on the information gathered from the hazard analysis program. The procedures shall incorporate industry guidance, such as the Center for Chemical Process Safety’s (CCPS) Guidelines for Risk-Based Process Safety and the CCPS’s Guidelines for Writing Effective Operating and Maintenance Procedures. c. A training program, including written materials, for the employees involved in the nitriding process. This program shall be based on the nitriding facility’s operating procedures and other relevant information from the hazard analysis program. The program shall incorporate industry guidance, such as the Center for Chemical Process Safety’s (CCPS) Guidelines for Risk-Based Process Safety. d. An incident investigation program. This program shall include requirements for performing causal analysis, producing written reports, and communicating findings and corrective actions throughout the entire TS USA organization. The program shall incorporate industry guidance, such as the Center for Chemical Process Safety’s (CCPS) Guidelines for Risk-Based Process Safety and the CCPS’s Guidelines for Investigating Process Safety Incidents.
From TS USA Molten Salt Eruption, May 30, 2024
Washington State Department of Labor & Industries - Division of Occupational Safety and Health · 2 open
- 2010-08-I-WA-8Open - Acceptable Response or Alternate Response
Perform a verification audit at all Washington petroleum refineries to ensure: a. Prevention of HTHA equipment failure and safe operation of the equipment. Audit HTHA prevention and process condition monitoring techniques used at all Washington petroleum refineries. Verify that all affected equipment in use meets the requirements contained in Recommendation 2010-08-I-WA-R10; b. For nonroutine work, a written hazard evaluation is performed by a multidisciplinary team and, where feasible, conducted during the job planning process prior to the day of the job execution. Verify that each facility has an effective written decision-making protocol used to determine when it is necessary to shut a process down to safely perform work or conduct repairs. Ensure the program reflects the guidance in the CCPS Risk Based Process Safety book related to hazardous nonroutine work; and c. Effective programs are in place to control of the number of essential personnel present during all hazardous nonroutine work.
From Tesoro Anacortes Refinery Fatal Explosion and Fire, April 2, 2010
- 2010-08-I-WA-9Open - Acceptable Response or Alternate Response
Effectively participate in the Tesoro Anacortes Refinery process safety culture survey oversight committee as recommended under recommendation 2010-08-I-WA-R15. Incorporate the expertise of process safety culture experts in the development and interpretation of the safety culture surveys. Ensure the effective participation of the workforce and their representatives in the development of the surveys and the implementation of corrective actions.
From Tesoro Anacortes Refinery Fatal Explosion and Fire, April 2, 2010
American Society of Safety Professionals (ASSP) · 1 open
- 2023-03-I-LA-4Open - Awaiting Response or Evaluation/Approval of Response
Update ANSI/ASSP Z117.1 Safety Requirements for Entering Confined Spaces to provide guidance on how to ensure that vessels that have undergone confined space entry are left clean and ready for startup after the entries are completed.
From Dow Louisiana Operations Explosions, July 14, 2023
Atchison County Department of Emergency Management · 1 open
- 2017-01-I-KS-5Open - Acceptable Response or Alternate Response
Coordinate planning and training activities to ensure emergency responders within Atchison County are prepared for future incidents involving hazardous materials. The Atchison County Local Emergency Planning Committee should do the following: a) Review facility Risk Management Plans as they are submitted or revised and conduct pre-planning at Risk Management Program covered facilities and all other facilities within the county that, based on annual Tier II reporting forms, store large amounts of hazardous chemicals. b) Conduct a full-scale hazardous materials exercise that involves an offsite chemical release scenario within the next three years. The exercise should include participants from local emergency response organizations, hospitals, schools, and fixed facilities. Identify and resolve coordination or communication issues identified during the exercise. c) Increase participation in state and regional emergency response training and programs. Work with the Kansas Department of Emergency Management to submit a Hazardous Materials Emergency Preparedness (HMEP) grant proposal to assist in funding additional training and pre-planning activities within the county.
From MGPI Processing, Inc. Toxic Chemical Release, October 20, 2016
Cenovus Superior Refinery · 1 open
- 2018-02-I-WI-3Open - Acceptable Response or Alternate Response
Develop and implement a slide valve mechanical integrity program that addresses erosion and ensures proper functioning of the slide valves during a shutdown. The program must include, at a minimum: a) A slide valve mechanical integrity standard that defines monitoring and inspection requirements, with acceptance criteria, required for the safe operation of the FCC unit during transient operation (such as a startup, shutdown, standby, and emergency). b) Monitoring that includes process data analysis and mechanical preventive activities to evaluate the mechanical condition of the slide valves during the operation of the FCC unit between turnarounds; c) Quarterly presentations of process data and mechanical preventive maintenance data to refinery operations management and maintenance management to drive key decisions such as shortening the turnaround cycle and/or planning a maintenance outage; d) During turnarounds and other potential slide valve maintenance outages, evaluate the adequacy of the slide valve mechanical integrity program for the safe operation of the FCC unit during transient operation. If the inspection demonstrates unsuccessful performance, make appropriate corrections. During the next major FCC unit turnaround at Cenovus Superior Refinery, demonstrate that the slide valve mechanical program is adequate for the safe operation of the FCC unit during transient operation. If the inspection demonstrates unsuccessful performance, make appropriate corrections to the slide valve mechanical integrity program.
From Husky Energy Superior Refinery Explosion and Fire, April 26, 2018
Department of the Interior (DOI) [delegated to DOI-BSEE] · 1 open
- 2010-10-I-OS-16Open - Awaiting Response or Evaluation/Approval of Response
Incorporate by reference into the offshore safety regulations the revised version of Recommended Practice 75, Development of a Safety and Environmental Management Program for Offshore Operations and Facilities, 3rd Ed., May 2004 (reaffirmed May 2008) upon the inclusion of the CSB recommendations in R11 by API.
From Macondo Blowout and Explosion, April 20, 2010
Dow Chemical Company · 1 open
- 2023-03-I-LA-1Open - Acceptable Response or Alternate Response
At all Dow ethylene oxide facilities, identify all process lines in ethylene oxide service that should be or are inerted and currently are not continuously monitored during normal operation. For all lines identified, determine whether the line can be eliminated, and if not, establish proper controls such as inerting and monitoring to ensure the process line is adequately inerted.
From Dow Louisiana Operations Explosions, July 14, 2023
Givaudan - Corporate · 1 open
- 2024-06-I-KY-8Open - Awaiting Response or Evaluation/Approval of Response
Create and fill a corporate senior leadership position responsible for overseeing process safety at all Givaudan caramel coloring facilities or identify a current senior leader who is competent in process safety management concepts to fill this role. Establish this senior leader’s job duties to oversee the process safety management system implementation at all Givaudan caramel coloring facilities. Assign this individual to develop corporate-level process safety management system policies to ensure consistent development and implementation of process safety management systems at all Givaudan caramel coloring facilities. One of the policies will address training operations personnel on defined safe operating limits and actions to take if those limits are exceeded.
From Givaudan Sense Colour Explosion, November 12, 2024
International Society of Automation (ISA) · 1 open
- 2022-01-I-OH-7Open - Acceptable Response or Alternate Response
Revise American National Standard ANSI/ISA 18.2-2016, Management of Alarm Systems for the Process Industries, to include performance targets for short-term alarm flood analysis so that users can evaluate alarm flood performance for a single alarm flood event. The performance targets should include: a) number of alarm floods, b) duration of each flood, c) alarm count in each flood, and d) peak alarm rate for each flood. At a minimum, a target peak alarm flood rate should be defined, such as in the guidance provided by the ASM Consortium or Engineering Equipment and Materials Users Association (EEMUA), to establish trigger points that require alarm performance improvement actions.
From BP - Husky Oregon Chemical Release and Fire, September 20, 2022
Kuraray America, Inc. · 1 open
- 2018-03-I-TX-1Open - Acceptable Response or Alternate Response
Develop and implement an emergency pressure-relief system design standard to ensure that each of these safety systems will discharge to a safe location. Include a requirement to periodically evaluate the site’s emergency pressure-relief systems and make appropriate modifications to ensure that each of these systems discharge to a safe location such that material that could discharge from these safety systems will not harm people.
From Kuraray Pasadena Release and Fire, May 19, 2018
Louisiana Governor and Legislature/Secretary of the Louisiana Department of Environmental Quality · 1 open
- 2020-05-I-LA-5Open - Awaiting Response or Evaluation/Approval of Response
Under existing statutory or regulatory authority or through the establishment of new authority by executive or legislative action, for all existing chemical manufacturing and storage facilities that: (1) Are located in a hurricane-prone region as defined by the International Building Code, and (2) Manufacture or store or can inadvertently or otherwise produce (e.g., by chemical reaction) regulated substances inside equipment or building(s) built before more current wind design requirements came into effect Require the facility operators to evaluate the hazards to their facilities from hurricanes and accompanying wind, rainwater, floodwater, or storm surge forces. Require the facility operators to implement processes and safeguards for protection against those hazards, such as through: a. Ensuring that buildings and structures (both new and existing) can withstand hurricane winds and flooding, with a particular focus on buildings and structures containing hazardous materials; b. Implementing safeguards and processes to ensure that hazardous chemicals are not compromised and released during extreme weather events; and/or c. Following the guidance presented in the Center for Chemical Process Safety Monograph Assessment of and Planning for Natural Hazards.
From Bio-Lab Lake Charles Chemical Fire and Release, August 27, 2020
Mayor, City of St. Louis, MO · 1 open
- 2017-04-I-MO-6Open - Unacceptable Response/No Response Received
Distribute and communicate the findings of this report to all licensed stationary engineers and all registered boiler and pressure vessel owning/operating entities in the City of St. Louis.
From Loy Lange Box Company Pressure Vessel Explosion, April 3, 2017
MPW Industrial Services, Inc. · 1 open
- 2025-03-I-PA-7Open - Awaiting Response or Evaluation/Approval of Response
Develop written policies and procedures in accordance with industry guidance such as NFPA 56 Standard for Fire and Explosion Prevention During Cleaning and Purging of Flammable Gas Piping Systems, governing cleaning piping systems containing flammable or toxic gas. Ensure that all workers who will or might participate in such operations are trained on the policies and procedures.
From United States Steel Corporation Clairton Plant Coke Oven Explosion, August 11, 2025
Nippon Steel North America, Inc. · 1 open
- 2025-03-I-PA-6Open - Awaiting Response or Evaluation/Approval of Response
Develop and implement a corporate process safety governance program to ensure the implementation of process safety management at applicable facilities. At a minimum, this program shall: a. include regular audits of subordinate facilities throughout the organization; b. require the documentation of process safety deficiencies, when identified, and prompt corrective action; and, c. incorporate industry guidance, such as the Center for Chemical Process Safety’s (CCPS) Guidelines for Implementing Process Safety Management, the CCPS’s Process Safety – Leadership from the Boardroom to the Frontline, and other industry good practice guidance publications.
From United States Steel Corporation Clairton Plant Coke Oven Explosion, August 11, 2025
Ohio Refining Company · 1 open
- 2022-01-I-OH-1Open - Acceptable Response or Alternate Response
Revise the safeguards used in the refinery’s process hazard analyses high level and overflow scenarios. At a minimum, establish effective preventive safeguards that use engineered controls to prevent liquid overfill and do not rely solely on human intervention.
From BP - Husky Oregon Chemical Release and Fire, September 20, 2022
Tennessee Division of Occupational Safety & Health (TOSHA) · 1 open
- 2021-01-I-TN-7Open - Unacceptable Response/No Response Received
Promulgate a standard or modify existing standards to require employers to ensure the coordination of simultaneous operations (SIMOPs) involving multiple work groups, including contractors. Ensure that the requirements of this standard or standards apply to both general industry and construction activities and are not limited to activities occurring within confined spaces. Include in the standard requirements for Employers to ensure that the following activities occur: a. Identification of potential SIMOPs; b. Identification of potential hazardous interactions; c. Evaluation and implementation of necessary safeguards to allow for safe SIMOPs; d. Coordination, including shared communication methods, between the SIMOPs; and e. Inclusion of emergency response personnel or services in the planning and coordination of the SIMOPs.
From Wacker Polysilicon Chemical Release, November 13, 2020
Valve Manufacturers Association of America · 1 open
- 2021-05-I-TX-6Open - Acceptable Response or Alternate Response
Work with ASME and API and develop a white paper to the Valve Manufacturers Association of America addressing the issue of plug valve design with a focus on the following: a. Recommend as an industry good practice that facilities using plug valves establish written procedures detailing the correct way to remove the plug valve actuator or gearbox for each specific plug valve design. b. For existing plug valves, recommend as an industry good practice for facilities to clearly mark all pressure-retaining components (for example, with paint, accompanying warning signs, etc.). Work with ASME and API to ensure a consistent methodology is specified to the industry. c. Recommend new plug valves be designed, consistent with Prevention through Design principles, to prevent the inadvertent removal of pressure-retaining components when removing the actuator or gearbox. Evaluate past plug valve incidents, and the associated plug valve designs involved in those incidents, when formulating a new plug valve design recommendation. Work with ASME and API to ensure a consistent design is recommended to the industry.
From LyondellBasell La Porte Fatal Chemical Release, July 27, 2021