Honeywell Geismar Chlorine and Hydrogen Fluoride Releases
Geismar, LA · January 23, 2023
What happened
A heat exchanger rupture resulted in the release of hydrogen fluoride (HF) gas, chlorine gas, and various other process fluids. No injuries occurred. The CSB is investigating a second incident at the facility that occurred on June 7, 2024. There was a release of hydrofluoric acid that seriously injured one worker.
Summary by the US Chemical Safety Board.
Lessons
Hominin's reading of what the investigation asks others to change. Each lesson names the recommendations it comes from.
An independent audit, followed to the last finding
A heat exchanger rupture released hydrogen fluoride and chlorine. The company was asked to commission a comprehensive third-party audit of the site's process safety systems and to require reports from the site until every finding is closed.
From recommendations 2023-02-I-LA-1, 2023-02-I-LA-2
Look for safer technology
The company was asked to carry out a safer technologies and alternatives analysis for the unit involved, meeting the requirements the recommendation sets out.
From recommendation 2023-02-I-LA-3
Safety recommendations
The CSB made 4 recommendations; 4 are still open.
To Environmental Protection Agency (EPA)
- 2023-02-I-LA-4Open - Awaiting Response or Evaluation/Approval of Response
Per the requirements in EPA Rule Procedures for Prioritization of Chemicals for Risk Evaluation Under the Toxic Substances Control Act, initiate prioritization to evaluate whether hydrogen fluoride, including its anhydrous and aqueous acid forms, is a High-Priority Substance for risk evaluation. If it is determined to be a High-Priority Substance, conduct a risk evaluation of hydrogen fluoride to determine whether it presents an unreasonable risk of injury to health or the environment. If it is determined to present an unreasonable risk of injury to health or the environment, apply requirements to hydrogen fluoride to the extent necessary to eliminate or significantly mitigate the risk, for example by using a methodology such as the hierarchy of controls. (Supersedes 2019-04-I-PA-R3 from the Philadelphia Energy Solutions Report)
To Honeywell International, Inc.
- 2023-02-I-LA-1Open - Acceptable Response or Alternate Response
Perform a comprehensive third-party audit of the Geismar facility’s process safety and allied management systems as soon as practicable. The audit shall: A. Be performed or led by an individual, firm, or team meeting the requirements outlined in paragraphs (b), (c), and (d) of Appendix E of this report. B. Evaluate compliance with applicable federal standards (40 C.F.R. § 68 and 29 C.F.R. § 1910.119). In particular, the audit shall include the required elements that contributed to these incidents, including but not limited to: 1. management of change; 2. mechanical integrity; 3. quality assurance; 4. pre-startup safety reviews; 5. operating procedures; and 6. contractor management. C. Evaluate other internal management systems that contributed to these incidents. In particular, the audit shall include but not be limited to: 1. management of organizational and personnel change; 2. management of safety-related capital projects; 3. organizational resilience; and 4. safe work practices including, but not limited to: a. work permitting; b. preparation of equipment for maintenance; c. control of hazardous energy; d. line break safety; and e. personal protective equipment. D. Use the Center for Chemical Process Safety’s Guidelines for Auditing Process Safety Management Systems as guidance to verify both the suitability of these systems and their effective, consistent implementation and performance. E. Result in the development of a comprehensive report meeting the requirements outlined in paragraphs (e) and (f) of Appendix E of this report. If any findings are rejected, the rationale for and documentation supporting the merit of the rejection shall be included. The report in its entirety shall be made available to the Honeywell workforce at the Geismar, Louisiana; Baton Rouge, Louisiana; and Metropolis, Illinois, sites.
- 2023-02-I-LA-2Open - Acceptable Response or Alternate Response
Require periodic reporting updates from the Geismar site regarding the closure of the audit findings. The periodic updates shall continue until all audit findings are fully closed.
- 2023-02-I-LA-3Open - Acceptable Response or Alternate Response
Perform a Safer Technologies and Alternatives Analysis (STAA) for the Honeywell Geismar HFC-245fa unit. The STAA shall meet the requirements outlined in paragraphs (a) and (b) of Appendix F of this report.
More release investigations
- PEMEX Deer Park Chemical Release · Deer Park, TX, 2024
- Cuisine Solutions Ammonia Release · Sterling, VA, 2024
- TS USA Molten Salt Eruption · Chattanooga, TN, 2024
- LyondellBasell La Porte Fatal Chemical Release · La Porte, TX, 2021