Chemical Manufacturing - Fire and Explosion
CSB Safety Study: Remote Isolation of Process Equipment
Safety bulletin or study · November 27, 2019
What happened
Over the last several years, the U.S. Chemical Safety and Hazard Investigation Board (CSB) has reviewed and investigated numerous incidents where the consequences escalated following a loss of containment due to the lack of effective remote isolation equipment. These incidents resulted in serious injuries, fatalities, environmental contamination, and severe damage to facilities.
Summary by the US Chemical Safety Board.
Safety recommendations
The CSB made 3 recommendations; 2 are still open.
To American Petroleum Institute (API)
- 2024-01-H-1Closed - Acceptable Action
Develop a new publication or revise an existing publication or publications that should be applicable to various facility types such as refineries, chemical and petrochemical facilities, terminals, etc. with major process equipment and atmospheric storage tanks, that details conditions that necessitate the installation of remote isolation devices [use “shall” instead of “should” language] that may be automatically activated or remotely activated from a safe location, particularly during an emergency. When establishing these conditions refer to the guidance published by CCPS entitled Guidelines for Fire Protection in Chemical, Petrochemical, and Hydrocarbon Processing Facilities, Sections 8.1.10 and 8.1.11. At a minimum, the conditions should address major process equipment and atmospheric storage tanks, material volumes/weight as well as flammability, corrosivity, and toxicity
To Environmental Protection Agency (EPA)
- 2024-01-H-2Open - Awaiting Response or Evaluation/Approval of Response
Update the Risk Management Program (RMP) rule by expanding the requirements of 40 CFR Part 68 to include an evaluation of the need for remote isolation devices for major process equipment that can be remotely activated from a safe location or automatically activated during a release. The evaluation should be included in hazard assessments, hazard reviews, and process hazard analyses.
To Occupational Safety and Health Administration (OSHA)
- 2024-01-H-3Open - Awaiting Response or Evaluation/Approval of Response
Update the Process Safety Management (PSM) standard by expanding the Process Hazard Analysis (PHA) requirements under 29 CFR 1910.119(e)(3) to include an evaluation of the need for remote isolation devices for major process equipment that can be remotely activated from a safe location or automatically activated during a release.
More chemical manufacturing - fire and explosion investigations
- Shell Polymers Furnace Explosion and Fire · Monaca, PA, 2025
- Optima Belle Explosion and Fire · Belle, WV, 2020
- Wacker Polysilicon Chemical Release · Charleston, TN, 2020