Release

D.D. Williamson & Co. Catastrophic Vessel Failure

Louisville, KY · April 11, 2003

What happened

On the morning of April 11, 2003, one worker was killed at the D.D. Williamson food additive plant in Louisville, Kentucky, when a process vessel became overpressurized and failed catastrophically. The failure caused a release of aqueous ammonia as well as extensive damage to the plant, which manufactures caramel coloring.

Summary by the US Chemical Safety Board.

Safety recommendations

The CSB made 10 recommendations; none is still open.

To Commonwealth of Kentucky

  • 2003-11-I-KY-7Closed - Acceptable Action

    Communicate to the owners of pressure vessels, mechanical contractors, engineering consulting companies, and insurance companies doing business in Kentucky that used pressure vessels are not exempt from registration and initial inspection before being placed in service in Kentucky.

To D.D. Williamson and Co., Inc.

  • 2003-11-I-KY-1Closed - Acceptable Action

    Institute procedures to ensure that pressure vessels are designed, fabricated, and operated according to applicable codes and standards.

  • 2003-11-I-KY-2Closed - Acceptable Action

    Audit all vessels at all D. D. Williamson facilities and ensure that they are: Equipped with adequate overpressure protection, as warranted. Equipped with alarms or interlocks, as warranted.

  • 2003-11-I-KY-3Closed - Acceptable Action

    Implement a program to review existing equipment when it is used for new purposes and when safety devices are removed or altered.

  • 2003-11-I-KY-4Closed - Acceptable Action

    Implement a hazard evaluation procedure to determine the potential for catastrophic incidents and necessary safeguards.

  • 2003-11-I-KY-5Closed - Acceptable Action

    Audit manual control of process conditions, such as temperature and pressure, and determine if safeguards are needed.

  • 2003-11-I-KY-6Closed - Acceptable Action

    Upgrade written operating procedures and train operators on the revised procedures.

To Mechanical Contractors Association of Kentucky

  • 2003-11-I-KY-8Closed - Acceptable Action

    Communicate to your members that used pressure vessels are not exempt from registration and initial inspection before being placed in service in Kentucky.

To National Board of Boiler and Pressure Vessel Inspectors (NBBI)

  • 2003-11-I-KY-10Closed - Acceptable Action

    Communicate the findings of this report to your membership.

To Risk and Insurance Management Society (RIMS)

  • 2003-11-I-KY-9Closed - Acceptable Action

    Communicate the findings of this report to your membership.