Skip to main content

Confined Space / Asphyxiation

Valero Delaware City Refinery Asphyxiation Incident

Delaware City, DE · November 5, 2005

What happened

Two contract employees were overcome and fatally injured by nitrogen as they performed maintenance work near a 24-inch opening on the top of a reactor. One of the workers died attempting rescue.

Summary by the US Chemical Safety Board.

Safety recommendations

The CSB made 8 recommendations; none is still open.

To American Petroleum Institute (API)

  • 2006-2-I-DE-6Closed - Acceptable Action

    Revise Guidelines for Safe Work in Inert Confined Spaces in the Petroleum and Petrochemical Industries (API, 2005) to clearly address the following: - An oxygen-deficient atmosphere rapidly overcomes the victim. - There is no warning before being overcome. - An oxygen-deficient atmosphere might exist outside a confined space opening. - Rescuers must strictly follow safe rescue procedures.

To American Society of Safety Engineers (ASSE)

  • 2006-2-I-DE-7Closed - Exceeds Recommended Action

    Revise Safety Requirements for Confined Spaces, ANSI/ASSE Z117.1 to emphasize that: - An oxygen-deficient atmosphere rapidly overcomes the victim. - There is no warning before being overcome. - An oxygen-deficient atmosphere might exist outside a confined space opening. - Rescuers must strictly follow safe rescue procedures.

To Compressed Gas Association (CGA)

  • 2006-2-I-DE-8Closed - Acceptable Action

    Issue a safety alert to address nitrogen/inert gas hazards in confined spaces. Emphasize that: - An oxygen-deficient atmosphere rapidly overcomes the victim. - There is no warning before being overcome. - An oxygen-deficient atmosphere might exist outside a confined space opening. - Rescuers must strictly follow safe rescue procedures.

To Matrix Service Industrial Contractors, Inc.

  • 2006-2-I-DE-5Closed - Acceptable Action

    Conduct confined space control and inert gas purge procedure refresher training for all affected personnel. Emphasize: - The requirements to maintain posted warnings at all access points to confined space temporary openings. - The need to maintain posted warnings, barricades, and access controls as required by the client. - An oxygen-deficient atmosphere rapidly overcomes the victim. - There is no warning before being overcome. - An oxygen-deficient atmosphere might exist outside a confined space opening. - Rescuers must strictly follow safe rescue procedures.

To Valero Delaware City Refinery

  • 2006-2-I-DE-1Closed - Acceptable Action

    Conduct safe work permit refresher training for all permit-preparers and approvers and affected refinery personnel and contractors. Emphasize: - All proposed work requires a jobsite visit by the requestor and a unit operator to identify special precautions, equipment status, and personal safety equipment requirements. - The conditions for marking the "nitrogen purge or inerted" (Yes/No/NA) status box. - The permit must clearly identify all hazards and special personal protective equipment requirements. - "Fresh Air" work restrictions apply to "Set up only" permits whenever an IDLH atmosphere is suspected or known to be present in the work area.

  • 2006-2-I-DE-2Closed - Acceptable Action

    Conduct confined space control and inert gas purge procedure refresher training for all affected refinery personnel and contractors. Emphasize: - The requirements to maintain posted warnings at all access points to confined space temporary openings. - The requirements to maintain posted warnings, barricades, and access control log at equipment during purging. - An oxygen-deficient atmosphere rapidly overcomes the victim. - There is no warning before being overcome. - An oxygen-deficient atmosphere might exist outside a confined space opening. - Rescuers must strictly follow safe rescue procedures.

To Valero Energy Corporation

  • 2006-2-I-DE-3Closed - Acceptable Action

    Audit work permit procedures and nitrogen purge safety procedures at each Valero U.S. refinery. Determine if issues identified in this Case Study are occurring elsewhere. Implement corrective action, including training, where necessary.

  • 2006-2-I-DE-4Closed - Acceptable Action

    Require Valero U.S. refineries to revise and conduct nitrogen hazards awareness training. Emphasize: - An oxygen-deficient atmosphere rapidly overcomes the victim. - There is no warning before being overcome. - An oxygen-deficient atmosphere might exist outside a confined space opening. - Rescuers must strictly follow safe rescue procedures.

More confined space / asphyxiation investigations