Morganton, NC · January 31, 2006

What happened

One worker was fatally burned and about a dozen others were injured when a powerful explosion devastated the Synthron Inc. chemical manufacturing facility. CSB investigators believe the explosion was related to the process inside a 1500-gallon batch reactor at the plant, which contained butyl acrylate along with the flammable solvents toluene and cyclohexane.

Summary by the US Chemical Safety Board.

Safety recommendations

The CSB made 1 recommendation; none is still open.

To Protex International

  • 2006-4-I-NC-1Closed - Acceptable Action

    Establish a program to ensure that reactive hazards at Protex U.S. facilities are managed in accordance with good industry practices. At a minimum, the program should: -identify and characterize reactive hazards; -implement, document, and maintain appropriate safeguards; -manage changes to recipes; -document and maintain safety critical process equipment capabilities; -train personnel on reactive hazards, safe operating limits, and the consequences of and responses to deviations; -train personnel on emergency evacuations alarms and procedures, and conduct emergency drills; and, -conduct periodic audits of program implementation to identify and address weaknesses.