HEAD BALLOONS INC AX8-88B
Albuquerque, NM, United States
Open the source record for aircraft details and available investigation material.
Loading the aviation accident library…
NTSB investigation record · Nov 4, 2023 (UTC)
Page, AZ, United States
WPR24LA029
A hard landing after both burner pilot lights extinguished during the landing approach for undetermined reasons. Contributing to the accident was the pilot's inability to relight the burner pilot lights.
The pilot of the balloon reported that while selecting an alternate landing area, both burners failed to ignite. The pilot unsuccessfully attempted to restart both burners with the piezo igniters. The pilot then took out a butane lighter to manually relight a pilot light, but he still could not relight it in time to arrest the balloon’s descent. The pilot informed the passengers that they were going to hit the ground hard. The basket hit a parked car, tilted downward momentarily, and then bounced off the road. After the basket contacted the ground and climbed 6 to 10 feet above ground level, one of the passengers fell out of the balloon and sustained a serious injury. With one fewer passenger, the balloon began to ascend. During that time, the pilot found one of the blast valves operative. No further malfunctions were observed for the duration of the flight. A functional test and burner examination was completed with no defects noted that would have precluded normal operation.
On November 4, 2023, at 0850 mountain standard time, an Aerostar International Inc. RX-8 balloon, N50466, was not damaged when it was involved in an accident near Page, Arizona. One passenger was seriously injured; the pilot and another passenger were not injured. The balloon was operated as a 14 Code of Federal Regulations Part 91 personal flight. According to the pilot, on the morning of the event the balloon crew arrived about 0630.and the balloon envelope was offloaded and prepared for flight. Both burners indicated normal operating pressures of about 110 psi, which was above the manufacturer’s minimum requirement of 44 psi. Each burner was ignited using its dedicated piezoelectric starter, and both functioned properly. Passengers were given a safety briefing, and at 0800 the balloon launched on its first flight. The flight was uneventful. After landing, the balloon was reboarded, and a second safety briefing was provided to two new passengers. During the second flight, the balloon ascended to 6,200 feet before the pilot initiated a descent to an altitude with winds more favorable for returning to the launch site. When winds shifted, the pilot selected an alternate landing area. After clearing a set of powerlines, the pilot planned to land on a road between single-level apartments. About 10 yards beyond the powerlines, while maintaining level flight, the pilot attempted to initiate a burn with either burner. Neither burner ignited. The pilot made multiple restart attempts with the piezoelectric ignition system but was unsuccessful. The pilot then attempted to use a secondary ignition source—a butane lighter—but this attempt also failed The balloon began descending toward the intended landing site on the road between the single-level apartments. The pilot advised the passengers to prepare for a hard landing. The balloon’s basket impacted the top edge of a parked vehicle, which caused the basket to rotate beyond the horizontal position (i.e., the basket laid over on its side tilting down). As the basket righted itself, one passenger fell out of the basket from about six to ten feet above the ground, sustaining serious injuries. The balloon and basket were not damaged. Immediately after the accident, the weight reduction from the missing passenger caused the balloon to ascend. At that time, the pilot activated the blast valve and noted that one of the burners began to function properly. He surmised that the pilot light may have been successfully ignited with the butane lighter before impact. He then opened the “metering” valve to allow a small flame to be constantly burning in case of another pilot light issue. The balloon then landed uneventfully. The pilot reported that, upon landing, the fuel gauges each indicated approximately 50% to 55% of the fuel remaining in the tanks.
The owner’s manual for the Aerostar International Inc. RX-8 stated in part for burner relighting procedures. “Should the pilot light become extinguished: 1. Open metering valve to allow very low flow. 2. Use igniter or similar heat source to relight burner. 3. Maintain metering valve at low setting to serve as pilot light. 4. Check that pilot light valves are open at burner and tank. 5. If pilot relights, continue flight as normal. 6. If pilot does not relight, land as soon as practical. If relight of any pilot source is impossible: 7. Prepare for emergency/hard landing.” The burners and their ignition systems were removed for postaccident inspection and a test run. Operational and functional checks, including ignition system testing, were completed with no defects noted; the reported malfunction could not be duplicated. The fuel (propane) tanks were not removed for testing. The burners were configured such that one 18-gallon propane tank connected to each burner; there was no cross-feed plumbed between the two burners or tanks.
Aircraft record 1
Aircraft-Aircraft oper/perf/capability-Performance/control parameters-Descent rate-Attain/maintain not possible
Included in the probable-cause statement
Aircraft record 1
Personnel issues-Task performance-Use of equip/info-(general)-Pilot
Included in the probable-cause statement
Aircraft record 1
Aircraft-Aircraft power plant-Power plant-(general)-Unknown/Not determined
Included in the probable-cause statement
Albuquerque, NM, United States
Open the source record for aircraft details and available investigation material.
Angwin, CA, United States
The pilot reported that before takeoff he observed light and variable winds in the area. During flight, he noted more consistent wind speed and direction at higher altitudes. As the balloon descended, the pilot observed changes in both wind direction and speed. At about 2,300 ft mean sea level, he identified a southeasterly wind and adjusted his altitude to allow additional time to align the balloon with his intended
Johnstown, PA, United States
The pilot of the hot air balloon was conducting tethered passenger-carrying operations during a carnival event. The pilot reported that four heavy-duty vehicles were used as tether anchor points. The balloon was cold inflated and then brought upright using the burners. The occupants were loaded into the basket and the door was closed. Two tether lines were secured to anchor vehicles while ground crew members continue
Pahrump, NV, United States
On June 18, 2026, at 0645 mountain daylight time, an Ultramagic SA N-300 balloon, N330LV, was substantially damaged when it was involved in an accident near Pahrump, Nevada. The pilot and 2 passengers were seriously injured; 7 passengers sustained minor injuries. The balloon was operated as a Title 14 Code of Federal Regulations Part 91 sightseeing flight. The pilot reported that after completing a safety briefing to